Literature DB >> 7662824

Photo-crosslinked copolymers of 2-hydroxyethyl methacrylate, poly(ethylene glycol) tetra-acrylate and ethylene dimethacrylate for improving biocompatibility of biosensors.

C P Quinn1, C P Pathak, A Heller, J A Hubbell.   

Abstract

A copolymer containing 88% 2-hydroxyethyl methacrylate (HEMA), 9% poly(ethylene glycol) (MW 18.5 kDa) tetra-acrylate and 3% ethylene dimethacrylate was prepared and evaluated for use as a biocompatible interface between glucose biosensors and tissue in the rat. The glucose sensor utilizes glucose oxidase that is electrically 'wired' to a gold current collector by a reduction-oxidation polymer. Coatings of the copolymer were crosslinked in situ on the sensors using long wavelength ultraviolet light and 2,2-dimethoxy-2-phenyl-acetophenone as the initiator. The effect these films had on the current response to glucose was measured. Over a glucose concentration range of 0-30 mM, the average percentage decrease in response was 45 +/- 28% (mean +/- 95% confidence interval) at 37 degrees C for films that were about 0.1 mm thick, an acceptable value. Copolymer-treated and control electrodes were implanted in the intrascapular subcutaneous tissue of male Sprague-Dawley rats for three days. The explanted samples were evaluated using scanning electron microscopy. The control electrodes were highly encapsulated with fibrous material, while the copolymer-treated electrodes induced much less encapsulation. The results show this copolymer to be a candidate as a biocompatible coating for electrically wired oxidoreductase-based subcutaneous biosensors.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7662824     DOI: 10.1016/0142-9612(95)98856-9

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  22 in total

1.  Prevascularized silicon membranes for the enhancement of transport to implanted medical devices.

Authors:  Kristan S Worthington; Luke A Wiley; Robert F Mullins; Budd A Tucker; Eric Nuxoll
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-08-28       Impact factor: 3.368

Review 2.  Engineering biomaterials to integrate and heal: the biocompatibility paradigm shifts.

Authors:  James D Bryers; Cecilia M Giachelli; Buddy D Ratner
Journal:  Biotechnol Bioeng       Date:  2012-05-24       Impact factor: 4.530

3.  Electrochemical biosensors for on-chip detection of oxidative stress from immune cells.

Authors:  Jun Yan; Valber A Pedrosa; James Enomoto; Aleksandr L Simonian; Alexander Revzin
Journal:  Biomicrofluidics       Date:  2011-09-20       Impact factor: 2.800

4.  Anti-inflammatory polymeric coatings for implantable biomaterials and devices.

Authors:  Amanda W Bridges; Andrés J García
Journal:  J Diabetes Sci Technol       Date:  2008-11

5.  Reduced acute inflammatory responses to microgel conformal coatings.

Authors:  Amanda W Bridges; Neetu Singh; Kellie L Burns; Julia E Babensee; L Andrew Lyon; Andrés J García
Journal:  Biomaterials       Date:  2008-09-19       Impact factor: 12.479

Review 6.  Biomaterials/tissue interactions: possible solutions to overcome foreign body response.

Authors:  Jacqueline M Morais; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  AAPS J       Date:  2010-02-09       Impact factor: 4.009

7.  A review of the biocompatibility of implantable devices: current challenges to overcome foreign body response.

Authors:  Yoshinori Onuki; Upkar Bhardwaj; Fotios Papadimitrakopoulos; Diane J Burgess
Journal:  J Diabetes Sci Technol       Date:  2008-11

8.  Continuous amperometric monitoring of glucose in a brittle diabetic chimpanzee with a miniature subcutaneous electrode.

Authors:  J G Wagner; D W Schmidtke; C P Quinn; T F Fleming; B Bernacky; A Heller
Journal:  Proc Natl Acad Sci U S A       Date:  1998-05-26       Impact factor: 11.205

Review 9.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

10.  Electrochemical sensor array for glucose monitoring fabricated by rapid immobilization of active glucose oxidase within photochemically polymerized hydrogels.

Authors:  Amos Mugweru; Becky L Clark; Michael V Pishko
Journal:  J Diabetes Sci Technol       Date:  2007-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.