Literature DB >> 7659728

Dose calculations in proton beams: range straggling corrections and energy scaling.

K R Russell1, E Grusell, A Montelius.   

Abstract

Three-dimensional dose planning systems employing accurate proton transport algorithms are essential for calculating absorbed dose distributions in proton therapy. In this paper, a pencil beam algorithm for the transport of protons in materials of interest for radiation therapy is developed. The Fermi-Eyges multiple-scattering theory is used to derive transport equations for calculating proton fluence and absorbed dose distributions. The multiple-scattering theory of Molière is used to predict mean square scattering angles and to develop an expression for calculating the root mean square (RMS) radial spread of a proton pencil beam, as a function of depth, in an arbitrary scattering material. A correction factor is suggested to account for the decrease in the radial spread at the end of the range due to range straggling. The effects of neglecting large-angle scattering events and the possibility of incorporating such events into the pencil beam algorithm are discussed. An energy scaling technique for determining the water-equivalent surface energy at a given depth in a heterogeneous scattering medium is developed. The water-equivalent energy, giving the same Molière scattering parameter B in water, is determined and the 1/e angle in water is scaled to the appropriate width in the scattering material. By using stored analytically or Monte Carlo calculated pencil beam distributions in water, the large-angle single-scattering events may be incorporated by approximating the scattering in an arbitrary material by the scattering in water for protons of the appropriate water-equivalent surface energy.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7659728     DOI: 10.1088/0031-9155/40/6/005

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  A GPU implementation of a track-repeating algorithm for proton radiotherapy dose calculations.

Authors:  Pablo P Yepes; Dragan Mirkovic; Phillip J Taddei
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

2.  A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries.

Authors:  David C Westerly; Xiaohu Mo; Wolfgang A Tomé; Thomas R Mackie; Paul M DeLuca
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

3.  Monte Carlo fast dose calculator for proton radiotherapy: application to a voxelized geometry representing a patient with prostate cancer.

Authors:  Pablo Yepes; Sharmalee Randeniya; Phillip J Taddei; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2008-12-10       Impact factor: 3.609