Literature DB >> 7656525

Retrograde radiological retrieval and replacement of double-J ureteric stents.

C W Wetton1, W M Gedroyc.   

Abstract

Internal double-J stents are used to maintain ureteral patency and require replacement within 4-6 months. We present our experience with 15 consecutive patients who had 35 internal ureteral stents retrieved and in whom 27 were successfully replaced, retrogradely under fluoroscopic control. The double-J stents were retrieved using an Amplatz gooseneck snare. Replacement was more successful in female patients, and was technically more difficult via an ileal conduit or transplant ureter. We found this new technique to be straightforward and well tolerated by the patients. The procedure was performed on an outpatient basis, and no serious complications were reported. This technique is considerably cheaper than cystoscopic replacement under epidural or general anaesthesia, and is recommended for the retrieval and replacement of internal ureteral plastic stents in most patients.

Entities:  

Mesh:

Year:  1995        PMID: 7656525     DOI: 10.1016/s0009-9260(05)83193-9

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  8 in total

1.  Clinical significance of ureteral stent removal by flexible cystoscopy on pain and satisfaction in young males: a prospective randomised control trial.

Authors:  Young Beom Jeong; A Ram Doo; Hyung Sub Park; Yu Seob Shin
Journal:  Urolithiasis       Date:  2015-10-31       Impact factor: 3.436

2.  A preliminary study of the variability in location of the ureteral orifices with bladder filling by fluoroscopic guidance: the gender difference.

Authors:  Insang Hwang; Sun-Ouck Kim; Ho-Song Yu; Eu-Chang Hwang; Seung-Il Jung; Taek-Won Kang; Dongdeuk Kwon; Kwangsung Park
Journal:  Int Urol Nephrol       Date:  2013-05-09       Impact factor: 2.370

3.  Manual Replacement of Double J Stent Without Fluoroscopy (Double j stent replacement).

Authors:  Osman Kose; Sacit Nuri Gorgel; Sait Ozbir; Sekan Yenigurbuz; Cengiz Kara
Journal:  Int Surg       Date:  2015-02

4.  Fluoroscopically guided retrograde replacement of ureteral stents.

Authors:  G Carrafiello; D Laganà; M Mangini; C Recaldini; M Dizonno; A Giorgianni; D Lumia; A Taborelli; S Cuffari; C Fugazzola
Journal:  Radiol Med       Date:  2007-09-20       Impact factor: 3.469

5.  Retrieval of proximally migrated double J ureteric stents in children using goose neck snare.

Authors:  Sivasankar Jayakumar; Mohamed Marjan; Key Wong; Amman Bolia; George K Ninan
Journal:  J Indian Assoc Pediatr Surg       Date:  2012-01

6.  Pain and satisfaction during rigid cystoscopic ureteral stent removal: a preliminary study.

Authors:  Jae Heon Kim; Sun Young Park; Mun Gyu Kim; Hoon Choi; Dan Song; Sung Woo Cho; Yun Seob Song
Journal:  BMC Urol       Date:  2014-11-18       Impact factor: 2.264

7.  Facilitate Stent Removal: Magnetic DJ Stent.

Authors:  Hakan Ozturk
Journal:  Urol Case Rep       Date:  2017-02-02

8.  A prospective and randomized comparison of rigid ureteroscopic to flexible cystoscopic retrieval of ureteral stents.

Authors:  Dehui Lai; Meiling Chen; Shifang Zha; Shawpong Wan
Journal:  BMC Urol       Date:  2017-04-21       Impact factor: 2.264

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.