Literature DB >> 7655476

Use of an in-shoe pressure measurement system in the management of patients with neuropathic ulcers or metatarsalgia.

M J Mueller1.   

Abstract

Many injuries to the foot appear to be caused by repeated, excessive plantar pressures. In-shoe pressure systems are capable of measuring pressures at the interface between the shoe or orthotic and the plantar foot during a given functional activity. The purpose of this article is to describe the use of an in-shoe pressure system as a tool to aid physical therapists in the management of patients with foot problems as a result of excessive plantar pressures. Case histories are provided that describe the application of an in-shoe pressure device in the management of one patient with a neuropathic ulcer and one patient with metatarsalgia. A discussion of the primary clinical and equipment considerations of using this type of device is included.

Entities:  

Mesh:

Year:  1995        PMID: 7655476     DOI: 10.2519/jospt.1995.21.6.318

Source DB:  PubMed          Journal:  J Orthop Sports Phys Ther        ISSN: 0190-6011            Impact factor:   4.751


  7 in total

1.  The effect of insoles on the incidence and severity of low back pain among workers whose job involves long-distance walking.

Authors:  S Shabat; T Gefen; M Nyska; Y Folman; R Gepstein
Journal:  Eur Spine J       Date:  2005-01-25       Impact factor: 3.134

Review 2.  [Orthopedic shoe treatment: Inserts].

Authors:  R Schuh; R Windhager
Journal:  Orthopade       Date:  2016-03       Impact factor: 1.087

3.  Effect of selected exercises on in-shoe plantar pressures in people with diabetes and peripheral neuropathy.

Authors:  Kshamata M Shah; Michael J Mueller
Journal:  Foot (Edinb)       Date:  2012-06-06

4.  Comparison of plantar-pressure distribution and clinical impact of anatomically shaped sandals, off-the-shelf sandals and normal walking shoes in patients with central metatarsalgia.

Authors:  Reinhard Schuh; Jessica Seegmueller; Axel H Wanivenhaus; Reinhard Windhager; Manuel Sabeti-Aschraf
Journal:  Int Orthop       Date:  2014-09-12       Impact factor: 3.075

5.  Dressing plantar wounds with foam dressings, is it too much pressure?

Authors:  Ryan Scott Causby; M Pod; Sara Jones
Journal:  Diabet Foot Ankle       Date:  2011-11-04

6.  Correlations between subjective treatment responses and plantar pressure parameters of metatarsal pad treatment in metatarsalgia patients: a prospective study.

Authors:  Jiunn-Horng Kang; Min-Der Chen; Shih-Ching Chen; Wei-Li Hsi
Journal:  BMC Musculoskelet Disord       Date:  2006-12-05       Impact factor: 2.362

7.  Investigation of Impact of Walking Speed on Forces Acting on a Foot-Ground Unit.

Authors:  Barbara Jasiewicz; Ewa Klimiec; Piotr Guzdek; Grzegorz Kołaszczyński; Jacek Piekarski; Krzysztof Zaraska; Tomasz Potaczek
Journal:  Sensors (Basel)       Date:  2022-04-18       Impact factor: 3.847

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.