Comparison of needle deviation during regional anesthetic techniques in a laboratory model.

D J Kopacz1, H W Allen.   

Abstract

Although many characteristics of needles used for spinal and epidural anesthesia have been studied extensively, the amount that a needle deviates from a straight path while passing through tissue has been relatively ignored. A laboratory model was used to determine the amount of needle deviation produced when different types of new spinal needles and epidural needles were passed through porcine tissue. Both needle point design and, to a lesser extent, needle gauge were found to influence the amount and direction of needle deviation. Deviation was found to be the least for the pencil-point spinal needles (Whitacre, Sprotte, Safetap, range 0.60-1.00 mm/50 mm tissue, analysis of variance (ANOVA) P < 0.001). Needles commonly used for epidural anesthesia (Tuohy, Hustead, Crawford) exhibited increased deviation (range 1.73-3.54 mm/50 mm tissue), although the largest amount was seen with beveled spinal needles (Quincke, Atraucan) (range 4.42-5.90 mm/50 mm tissue). The possible clinical significance of needle deviation during the performance of a regional anesthetic is discussed.

Entities:  

Mesh:

Year:  1995        PMID: 7653834     DOI: 10.1097/00000539-199509000-00037

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  6 in total

1.  Incorrect needle position during lumbar epidural steroid administration: inaccuracy of loss of air pressure resistance and requirement of fluoroscopy and epidurography during needle insertion.

Authors:  Walter S Bartynski; Stephen Z Grahovac; William E Rothfus
Journal:  AJNR Am J Neuroradiol       Date:  2005-03       Impact factor: 3.825

2.  Abstracts Presented at the Spring Meeting of the Society for Education in Anesthesia: Scoring Anesthesia Education: International Perspectives," Hilton Montreal Bonaventure, Montreal, Quebec, June 6 - 8, 2003.

Authors:  Armin Schubert
Journal:  J Educ Perioper Med       Date:  2003-07-01

3.  Characterization of pre-curved needles for steering in tissue.

Authors:  Thomas R Wedlick; Allison M Okamura
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2009

4.  [Intended and actual paths of epidural needles. Investigations with a test tissue model].

Authors:  H Baumann; J Biscoping
Journal:  Anaesthesist       Date:  2007-08       Impact factor: 1.041

5.  Real-time probe tracking using EM-optical sensor for MRI-guided cryoablation.

Authors:  Wenpeng Gao; Baichuan Jiang; Daniel F Kacher; Barry Fetics; Erez Nevo; Thomas C Lee; Jagadeesan Jayender
Journal:  Int J Med Robot       Date:  2017-11-28       Impact factor: 2.547

6.  Comparison of Spinal Needle Deflection in a Ballistic Gel Model.

Authors:  Ethan Rand; George Christolias; Christopher Visco; Jaspal R Singh
Journal:  Anesth Pain Med       Date:  2016-05-30
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.