Literature DB >> 7646167

Durability of the Carpentier-Edwards porcine bioprosthesis: role of age and valve position.

J M Bernal1, J M Rabasa, R Lopez, J F Nistal, R Muñiz, J M Revuelta.   

Abstract

The durability (structural deterioration-free interval) after valve implantation with the first-generation Carpentier-Edwards porcine bioprosthesis has been investigated. From 1978 through 1984, 420 patients (175 male, 245 female) underwent valve replacement with the Carpentier-Edwards standard bioprosthesis. Mean age was 50.6 years (range, 13 to 77 years). Isolated mitral valve replacement (MVR) was performed in 198 patients (47.1%), aortic valve replacement (AVR) in 136 (32.4%), and double valve replacement (DVR) in 86 (20.5%). Hospital mortality was 32 patients (7.6%), 7.5% for MVR, 5.1% for AVR, and 11.6% for DVR. Mean follow-up was 10.8 years (range, 9 to 15 years) and is 96.2% completed. Reoperation for structural deterioration was required in 143 patients. Actuarial curve free from structural deterioration at 15 years is 33.0% +/- 6.5% for MVR, 62.0% +/- 5.1% for AVR, and 44.2% +/- 8.2% for DVR (p < 0.03). Durability of the CE bioprosthesis for MVR was 101.6 +/- 34.5 months, 92.9 +/- 26.4 for AVR, and 84.3 +/- 25.3 for DVR (p = not significant). The regression logistic analysis between age at the time of surgery and durability of the bioprosthesis showed no correlation for the MVR group, but with the following predictive formula for AVR and DVR groups of patients older than 30 years" durability = 46.05 + 0.818 x age, for AVR (r2 = 0.43); durability = 15.81 + 1.122 x age, for DVR (r2 = 0.52). In conclusion, we have found a significant difference in the behavior of the CE porcine bioprosthesis between the mitral and aortic position.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7646167     DOI: 10.1016/0003-4975(95)00218-a

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  Sutured calf pericardium: influence of the type and angle of the suture on mechanical behavior.

Authors:  J M García Páez; E Jorge Herrero; M Martín Maestro; A Rocha; B Arenaz; J L Castillo-Olivares; A Carrera Sanmartín; A Cordon; I Millán
Journal:  J Mater Sci Mater Med       Date:  2003-05       Impact factor: 3.896

2.  A case of an explanted 26-year-old Carpentier-Edwards supra-annular valve in the tricuspid position.

Authors:  Shigeki Koizumi; Naoto Fukunaga; Tadashi Ikeda; Tadaaki Koyama
Journal:  J Cardiol Cases       Date:  2016-11-16

3.  Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation.

Authors:  J P A Puvimanasinghe; J J M Takkenberg; M B Edwards; M J C Eijkemans; E W Steyerberg; L A Van Herwerden; K M Taylor; G L Grunkemeier; J D F Habbema; A J J C Bogers
Journal:  Heart       Date:  2004-10       Impact factor: 5.994

4.  Evaluation and management of aortic valve and root disease.

Authors:  John B de Graft-Johnson; Thomas G Gleason
Journal:  Curr Treat Options Cardiovasc Med       Date:  2007-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.