Mechanical and dosimetric quality control for computer controlled radiotherapy treatment equipment.

A V Thompson1, K L Lam, J M Balter, D L McShan, M K Martel, T A Weaver, B A Fraass, R K Ten Haken.   

Abstract

Modern computer controlled radiotherapy treatment equipment offers the possibility of delivering complex, multiple field treatments with minimal operator intervention, thus making multiple field conformal therapy practical. Conventional quality control programs are inadequate for this new technology, so new quality control procedures are needed. A reasonably fast, sensitive, and complete daily quality control program has been developed in our clinic that includes nearly automated mechanical as well as dosimetric tests. Automated delivery of these quality control fields is performed by the control system of the MM50 racetrack microtron, directed by the CCRS sequence processor [D. L. McShan and B. A. Fraass, Proceedings of the XIth International Conference on the use of computers in Radiation Therapy, 20-24 March 1994, Manchester, U.K. (North Western Medical Physics Department, Manchester, U.K., 1994), pp. 210-211], which controls the treatment process. The mechanical tests involve multiple irradiations of a single film to check the accuracy and reproducibility of the computer controlled setup of gantry and collimator angles, table orientation, collimator jaws, and multileaf collimator shape. The dosimetric tests, which involve multiple irradiations of an array of ionization chambers in a commercial dose detector (Keithly model 90100 Tracker System) rigidly attached to the head of the treatment gantry, check the output and symmetry of the treatment unit as a function of gantry and collimator angle and other parameters. For each of the dosimetric tests, readings from the five ionization chambers are automatically read out, stored, and analyzed by the computer, along with the geometric parameters of the treatment unit for that beam.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7643792     DOI: 10.1118/1.597542

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  2 in total

1.  QA issues for computer-controlled treatment delivery: this is not your old R/V system any more!

Authors:  Benedick A Fraass
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008       Impact factor: 7.038

2.  Effect of esaxerenone on nocturnal blood pressure and natriuretic peptide in different dipping phenotypes.

Authors:  Kazuomi Kario; Sadayoshi Ito; Hiroshi Itoh; Hiromi Rakugi; Yasuyuki Okuda; Satoru Yamakawa
Journal:  Hypertens Res       Date:  2021-10-15       Impact factor: 3.872

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.