MR monitoring of focused ultrasonic surgery of renal cortex: experimental and simulation studies.

K Hynynen1, C A Damianou, V Colucci, E Unger, H H Cline, F A Jolesz.   

Abstract

The aim of the study was to test the hypothesis that magnetic resonance (MR) imaging-guided and -monitored noninvasive ultrasonic surgery can be performed in highly perfused tissues from outside the body. A simulation study was performed to evaluate the optimal sonication parameters. An MR-compatible positioning device was then used to manipulate a focused ultrasound transducer in an MR imager, which was used to sonicate kidneys of five rabbits at various power levels and different durations. Temperature elevation during sonication was monitored with a T1-weighted spoiled gradient-echo sequence. The simulation study demonstrated that a sharply focused transducer and relatively short sonication times (30 seconds or less) are necessary to prevent damage to the overlying skin and muscle tissue, which have a much lower blood perfusion rate than kidney. The experiments showed that the imaging sequence was sensitive enough to show temperature elevation during sonication, thereby indicating the location of the beam focus. Histologic evaluations showed that kidney necrosis could be consistently induced without damage to overlying skin and muscle. The study demonstrated that highly perfused tissues such as the renal cortex can be coagulated from outside the body with focused ultrasound and that MR imaging can be used to guide and monitor this surgery.

Entities:  

Mesh:

Year:  1995        PMID: 7633101     DOI: 10.1002/jmri.1880050306

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  8 in total

1.  MRI-compatible positioning device for guiding a focused ultrasound system for transrectal treatment of prostate cancer.

Authors:  Christos Yiallouras; Nicos Mylonas; Christakis Damianou
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-12-13       Impact factor: 2.924

2.  Fast temperature optimization of multi-source hyperthermia applicators with reduced-order modeling of 'virtual sources'.

Authors:  Kung-Shan Cheng; Vadim Stakhursky; Oana I Craciunescu; Paul Stauffer; Mark Dewhirst; Shiva K Das
Journal:  Phys Med Biol       Date:  2008-02-25       Impact factor: 3.609

3.  A new design method for extracorporeal high-intensity focused ultrasound annular array.

Authors:  Gin-Shin Chen; Yu-Cheng Lin; Chu-Chiang Chen
Journal:  Med Biol Eng Comput       Date:  2015-03-10       Impact factor: 2.602

4.  Model predictive filtering for improved temporal resolution in MRI temperature imaging.

Authors:  Nick Todd; Allison Payne; Dennis L Parker
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

5.  The effects of spatial sampling choices on MR temperature measurements.

Authors:  Nick Todd; Urvi Vyas; Josh de Bever; Allison Payne; Dennis L Parker
Journal:  Magn Reson Med       Date:  2010-09-29       Impact factor: 4.668

6.  Toward real-time availability of 3D temperature maps created with temporally constrained reconstruction.

Authors:  Nick Todd; Jaya Prakash; Henrik Odéen; Josh de Bever; Allison Payne; Phaneendra Yalavarthy; Dennis L Parker
Journal:  Magn Reson Med       Date:  2013-05-13       Impact factor: 4.668

7.  A quality control program for MR-guided focused ultrasound ablation therapy.

Authors:  Tao Wu; Joel P Felmlee
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

8.  An experimental model to investigate the targeting accuracy of MR-guided focused ultrasound ablation in liver.

Authors:  Lorena Petrusca; Magalie Viallon; Romain Breguet; Sylvain Terraz; Gibran Manasseh; Vincent Auboiroux; Thomas Goget; Loredana Baboi; Patrick Gross; K Michael Sekins; Christoph D Becker; Rares Salomir
Journal:  J Transl Med       Date:  2014-01-16       Impact factor: 5.531

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.