Intravenous albunex during dobutamine stress echocardiography: enhanced localization of left ventricular endocardial borders.

R A Falcone1, P A Marcovitz, J E Perez, H C Dittrich, W E Hopkins, W F Armstrong.   

Abstract

Albunex is an intravenous contrast agent that opacifies the left ventricle (LV). This study evaluated the effect of Albunex on the enhancement of LV endocardial border localization during dobutamine stress echocardiography (DSE). Albunex was infused in 30 patients at baseline and with low- and high-dosage dobutamine. Apical two- and four-chamber views were divided into six segments each, and enhancement of LV border localization was compared with precontrast images graded as follows: 0 = none; 1 = faint; or 2 = optimal. The mean grade and percentage of segments with optimal localization of LV endocardial borders were determined. There was a significant increase in enhancement with low- and high-dosage dobutamine when compared with baseline. Of 179 segments with suboptimal enhancement at baseline, 137 (77%) became optimal during DSE with Albunex. We conclude that Albunex improves localization of LV endocardial borders and that this localization is enhanced during DSE.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7631604     DOI: 10.1016/0002-8703(95)90437-9

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  8 in total

Review 1.  Added value of contrast echocardiography in assessing myocardial viability.

Authors:  A Nagy; F L Dini; D Rovai
Journal:  Heart       Date:  1999-11       Impact factor: 5.994

2.  An enhanced method for left ventricular volume and ejection fraction by triggered harmonic contrast echocardiography.

Authors:  K Hirooka; Y Yasumura; Y Tsujita; A Hanatani; S Nakatani; K Miyatake; M Yamagishi
Journal:  Int J Cardiovasc Imaging       Date:  2001-08       Impact factor: 2.357

3.  Sonovue improves endocardial border detection and variability in assessing wall motion score and ejection fraction during stress echocardiography.

Authors:  A S Brown; M Calachanis; C Evdoridis; J Hancock; S Wild; A Prasan; P Nihoyannopoulos; M J Monaghan
Journal:  Ir J Med Sci       Date:  2004 Jan-Mar       Impact factor: 1.568

4.  Clinical application and laboratory protocols for performing contrast echocardiography.

Authors:  Adrian Chong; Brian Haluska; Sudhir Wahi
Journal:  Indian Heart J       Date:  2013-04-06

5.  Non-contrast second harmonic imaging improves interobserver agreement and accuracy of dobutamine stress echocardiography in patients with impaired image quality.

Authors:  A Franke; R Hoffmann; H P Kühl; W Lepper; O A Breithardt; M Schormann; P Hanrath
Journal:  Heart       Date:  2000-02       Impact factor: 5.994

6.  Reproducibility of stress echocardiography using intravenous injection of ultrasound contrast agent (BY 963).

Authors:  R Leischik; C Kuhlmann; C Bruch; A Jeremias; T Buck; R Erbel
Journal:  Int J Card Imaging       Date:  1997-10

Review 7.  [Improved endocardium imaging using modified transthoracic echocardiography with the second harmonic frequency (tissue harmonic imaging)].

Authors:  H Becher; K Tiemann
Journal:  Herz       Date:  1998-12       Impact factor: 1.443

Review 8.  New ultrasound contrast agents for left ventricular and myocardial opacification.

Authors:  J D Kasprzak; F J Ten Cate
Journal:  Herz       Date:  1998-12       Impact factor: 1.443