A partial factor V deficiency in anticoagulated lyophilized plasmas has been identified as a cause of the international normalized ratio discrepancy in the external quality assessment scheme.

A Tripodi1, V Chantarangkul, B Akkawat, M Clerici, P M Mannucci.   

Abstract

Lyophilized normal and anticoagulated plasmas are increasingly used in External Quality Assessment schemes (EQAS) to assess the quality of performance of laboratories engaged in the control of oral anticoagulant therapy by means of the International Normalized Ratio (INR) system and for the standardization of the prothrombin time (PT). The main feature of the INR system is that the value measured for an individual plasma should be independent of the reagent used. This holds true only if the variable factors influencing the responsiveness of the reagents are the vitamin K-dependent clotting factors, the other factors being constant and within normal limits. We provide evidence that even a partial factor V (FV) deficiency (FV activity < 60 U/dl) in anticoagulated plasmas can be responsible for discrepancies between INR values as measured for a single lyophilized or fresh plasma by different reagents and that the discrepancy is proportional to and magnified by the International Sensitivity Index (ISI) of the reagent used. The greater the difference between ISI values, the wider the gap between INR values. Since FV is one of the most labile plasma clotting factors, its activity is likely to be lost during freeze-drying. Hence, we recommend a thorough control of the FV activity in commercial and home-made lyophilized plasmas before their use in EQAS and in the standardization of the PT.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7631309     DOI: 10.1016/0049-3848(95)00061-u

Source DB:  PubMed          Journal:  Thromb Res        ISSN: 0049-3848            Impact factor:   3.944


  4 in total

1.  Local INR correction: justification for a simplified approach.

Authors:  S Craig; K J Stevenson; J M Dufty; D A Taberner
Journal:  J Clin Pathol       Date:  1997-09       Impact factor: 3.411

2.  Clinical usefulness of international normalized ratio calibration of prothrombin time in patients with chronic liver disease.

Authors:  Jun Hyung Lee; Oh Joo Kweon; Mi-Kyung Lee; Hyun Woong Lee; Hyung Joon Kim; Hye Ryoun Kim
Journal:  Int J Hematol       Date:  2015-06-12       Impact factor: 2.490

3.  Field study of lyophilised plasmas for local prothrombin time calibration in The Netherlands.

Authors:  A M van den Besselaar
Journal:  J Clin Pathol       Date:  1997-05       Impact factor: 3.411

4.  Analysis of risk factors for hepatic sinusoidal obstruction syndrome following allogeneic hematopoietic stem cell transplantation in pediatric patients.

Authors:  Jaspar Kloehn; Grit Brodt; Jana Ernst; Bernd Gruhn
Journal:  J Cancer Res Clin Oncol       Date:  2021-07-13       Impact factor: 4.322

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.