In vitro measurement of corneal strain, thickness, and curvature using digital image processing.

J O Hjortdal1, P K Jensen.   

Abstract

A video camera, a microscope, and a PC-based digital image processing board were assembled for in vitro studies of corneal biomechanics. Central tangential corneal strain was determined by placing pairs of tiny mercury droplets on the epithelial surface and on the endothelial surface of the cornea. A distance of 3.2 mm could be determined with a standard deviation of 1.2 micron. Central corneal radius of curvature was measured from digital traces of the corneal surface contour. The standard deviation on estimating the radius of an 8 mm steel sphere was 15 microns. Corneal thickness was measured by digital optical pachometry. The standard deviation on measuring a thickness of 1 mm was 4.6 microns. The corneal extensibility was investigated in a total of 10 enucleated human eyes with increased corneal hydration. Tension was applied by varying the intraocular pressure from 2 to 100 mmHg with a column of isotonic saline. The epithelial side corneal strain and the increase in corneal curvature were approximately 1% for a change in intraocular pressure from 2 to 100 mmHg. When a high intraocular pressure was kept constant for 2 h the corneal thickness, radius of curvature, and the epithelial side strain gradually decreased, whereas the endothelial side strain increased. The elastic and visco-elastic behaviour of the human cornea was found to be closely related to changes in corneal hydration. We found digital image processing useful for in vitro biomechanical studies of the cornea.

Entities:  

Mesh:

Year:  1995        PMID: 7627759     DOI: 10.1111/j.1600-0420.1995.tb00004.x

Source DB:  PubMed          Journal:  Acta Ophthalmol Scand        ISSN: 1395-3907


  25 in total

1.  In vitro effect of corneal collagen cross-linking on corneal hydration properties and stiffness.

Authors:  Georgios A Kontadakis; Harilaos Ginis; Nikolaos Karyotakis; Alexandros Pennos; Iro Pentari; George D Kymionis; Ioannis G Pallikaris
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-06-23       Impact factor: 3.117

2.  The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.

Authors:  P-A Tonnu; T Ho; T Newson; A El Sheikh; K Sharma; E White; C Bunce; D Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

Review 3.  Biomechanics and wound healing in the cornea.

Authors:  William J Dupps; Steven E Wilson
Journal:  Exp Eye Res       Date:  2006-05-23       Impact factor: 3.467

Review 4.  Microelectromechanical systems and nephrology: the next frontier in renal replacement technology.

Authors:  Steven Kim; Shuvo Roy
Journal:  Adv Chronic Kidney Dis       Date:  2013-11       Impact factor: 3.620

5.  Effect of glaucoma medications on 24-hour intraocular pressure-related patterns using a contact lens sensor.

Authors:  Kaweh Mansouri; Felipe A Medeiros; Robert N Weinreb
Journal:  Clin Exp Ophthalmol       Date:  2015-08-16       Impact factor: 4.207

6.  Serial biomechanical comparison of edematous, normal, and collagen crosslinked human donor corneas using optical coherence elastography.

Authors:  Matthew R Ford; Abhijit Sinha Roy; Andrew M Rollins; William J Dupps
Journal:  J Cataract Refract Surg       Date:  2014-04-24       Impact factor: 3.351

7.  A soft and transparent contact lens for the wireless quantitative monitoring of intraocular pressure.

Authors:  Joohee Kim; Jihun Park; Young-Geun Park; Eunkyung Cha; Minjae Ku; Hyeon Seok An; Kyoung-Pil Lee; Man-Il Huh; Junmo Kim; Taek-Soo Kim; Dai Woo Kim; Hong Kyun Kim; Jang-Ung Park
Journal:  Nat Biomed Eng       Date:  2021-05-03       Impact factor: 25.671

8.  MR elastography of the ex vivo bovine globe.

Authors:  Daniel V Litwiller; Sung J Lee; Arunark Kolipaka; Yogesh K Mariappan; Kevin J Glaser; Jose S Pulido; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2010-07       Impact factor: 4.813

9.  Continuous 24-hour monitoring of intraocular pressure patterns with a contact lens sensor: safety, tolerability, and reproducibility in patients with glaucoma.

Authors:  Kaweh Mansouri; Felipe A Medeiros; Ali Tafreshi; Robert N Weinreb
Journal:  Arch Ophthalmol       Date:  2012-12

Review 10.  Is 24-hour intraocular pressure monitoring necessary in glaucoma?

Authors:  Kaweh Mansouri; Robert N Weinreb; Felipe A Medeiros
Journal:  Semin Ophthalmol       Date:  2013-05       Impact factor: 1.975

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.