Literature DB >> 7618675

Comparison of direct blood pressure measurement at the radial and dorsalis pedis arteries during surgery in the horizontal and reverse Trendelenburg positions.

T Parry1, N Hirsch, N Fauvel.   

Abstract

The differences in simultaneous arterial pressure measurements from the radial and dorsalis pedis arteries were studied in anaesthetised adult patients in either the horizontal or reverse Trendelenburg position. Significantly higher pressures were measured from the dorsalis pedis artery than from the radial artery in both positions, even allowing for the hydrostatic effect on the dorsalis pedis arterial pressure in the non-horizontal group. If the dorsalis pedis artery is to be used to measure direct arterial blood pressure, we recommend that readings be compared with an arm sphygmomanometer to avoid potentially dangerous hypotension being missed.

Entities:  

Mesh:

Year:  1995        PMID: 7618675     DOI: 10.1111/j.1365-2044.1995.tb06052.x

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  3 in total

1.  The effect of variable arterial transducer level on the accuracy of pulse contour waveform-derived measurements in critically ill patients.

Authors:  Huai-Wu He; Da-Wei Liu; Yun Long; Xiao-Ting Wang; Mei-Ling Zhao; Xiao-Li Lai
Journal:  J Clin Monit Comput       Date:  2015-08-23       Impact factor: 2.502

2.  Study for the discrepancy of arterial blood pressure in accordance with method, age, body part of measurement during general anesthesia using sevoflurane.

Authors:  Ji Ho Lee; Joung-Min Kim; Ki Ryang Ahn; Chun Sook Kim; Kyu Sik Kang; Jin Hun Chung; Ji-Won Chung; Sie Hyeon Yoo
Journal:  Korean J Anesthesiol       Date:  2011-05-31

3.  Modalities of Invasive Arterial Pressure Monitoring in Critically Ill Patients: A Prospective Observational Study.

Authors:  Gwenaëlle Jacq; Karine Gritti; Cécile Carré; Nadège Fleury; Annie Lang; Josette Courau-Courtois; Jean-Pierre Bedos; Stephane Legriel
Journal:  Medicine (Baltimore)       Date:  2015-09       Impact factor: 1.817

  3 in total