Literature DB >> 7616775

Modelling and gait evaluation of asymmetrical-keel foot prosthesis.

P Allard1, F Trudeau, F Prince, J Dansereau, H Labelle, M Duhaime.   

Abstract

The paper documents a new concept in prosthetic foot design. It is based on the capacity of a flexible keel to allow a greater medio-lateral function than previously available. The heel has a complex curvature consisting of a medially concave shape that joins the mid-foot. There a hump acting as a leaf-spring ends at the metatarsal break, with an inwardly curved toe extremity. These curvatures contribute to increased medio-lateral control at heel-strike and propulsion for weight transfer and push-off. Results from finite-element modelling indicate that the asymmetrically shaped keel is at least twice as active in storing energy compared with a completely symmetrical one. A preliminary gait study is carried out for a 24-year-old below-knee amputee fitted with the new design, the SPACE foot and a dynamic elastic response foot with a symmetrical keel. With the SPACE foot, there is a 14% increase in walking speed combined with a reduction in the phasic asymmetries. The absolute difference between the initial and terminal double support is 1.4% for the asymmetrical keel design compared with 4.4% for the symmetrical keel foot prosthesis. The peak ankle power generation burst indicates that the SPACE foot behaves as a dynamic elastic response foot.

Mesh:

Year:  1995        PMID: 7616775     DOI: 10.1007/BF02522937

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  6 in total

1.  Below-knee amputee gait with dynamic elastic response prosthetic feet: a pilot study.

Authors:  L Torburn; J Perry; E Ayyappa; S L Shanfield
Journal:  J Rehabil Res Dev       Date:  1990

2.  Biomechanical analysis of the influence of prosthetic feet on below-knee amputee walking.

Authors:  A Gitter; J M Czerniecki; D M DeGroot
Journal:  Am J Phys Med Rehabil       Date:  1991-06       Impact factor: 2.159

3.  Running gait impulse asymmetries in below-knee amputees.

Authors:  F Prince; P Allard; R G Therrien; B J McFadyen
Journal:  Prosthet Orthot Int       Date:  1992-04       Impact factor: 1.895

4.  Biomechanics of below-knee amputee gait.

Authors:  D A Winter; S E Sienko
Journal:  J Biomech       Date:  1988       Impact factor: 2.712

5.  Comparison of gait between young adults fitted with the space foot and nondisabled persons.

Authors:  F Prince; P Allard; B J McFadyen; R Aissaoui
Journal:  Arch Phys Med Rehabil       Date:  1993-12       Impact factor: 3.966

6.  Role of the posterior calf muscles in normal gait.

Authors:  S R Simon; R A Mann; J L Hagy; L J Larsen
Journal:  J Bone Joint Surg Am       Date:  1978-06       Impact factor: 5.284

  6 in total
  2 in total

1.  Systematic methodology for the design of a flexible keel for energy-storing prosthetic feet.

Authors:  T S Jang; J J Lee; D H Lee; Y S Yoon
Journal:  Med Biol Eng Comput       Date:  2001-01       Impact factor: 2.602

2.  Prosthetic push-off power in trans-tibial amputee level ground walking: A systematic review.

Authors:  Roy Müller; Lisa Tronicke; Rainer Abel; Knut Lechler
Journal:  PLoS One       Date:  2019-11-19       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.