Routine urinalysis in renal transplant patients.

P Hashmi1, C Ho, S Morgan, J R Stephenson.   

Abstract

The performance of two commercially available urine dipstick tests was evaluated to exclude significant bacteriuria in midstream urine samples from patients attending a renal transplant outpatient clinic. The use of dipsticks to reduce the necessity for routine microscopy and culture was also assessed. Consecutive urine samples (n = 497) from 121 patients were examined for leucocytes, nitrite, and blood with Multistix* 10SG (Ames) and Nephur test (Boehring) dipsticks. All urine samples also underwent routine microscopy and culture. The sensitivities of the Nephur test and Multistix were 83% and 82%, respectively; the specificities were 28% and 40%, respectively; the negative predictive values were 85% and 88%, respectively; and the positive predictive values were 24% and 29%, respectively. Underlying conditions and treatments in renal patients may have led to relatively low sensitivity and positive predictive values. Traditional microscopy and culture methods are more reliable for renal transplant recipients.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7615863      PMCID: PMC502562          DOI: 10.1136/jcp.48.4.383

Source DB:  PubMed          Journal:  J Clin Pathol        ISSN: 0021-9746            Impact factor:   3.411


  5 in total

1.  URINARY CELL COUNTS AND THEIR VALUE.

Authors:  W BRUMFITT
Journal:  J Clin Pathol       Date:  1965-07       Impact factor: 3.411

2.  Evaluation of six screening methods for detecting significant bacteriuria.

Authors:  T K Smith; A J Hudson; R C Spencer
Journal:  J Clin Pathol       Date:  1988-08       Impact factor: 3.411

3.  Screening urine specimen populations for normality using different dipsticks: evaluation of parameters influencing sensitivity and specificity.

Authors:  C M Bank; J F Codrington; M P van Dieijen-Visser; P J Brombacher
Journal:  J Clin Chem Clin Biochem       Date:  1987-05

4.  Factors affecting the reliability of screening tests for bacteriuria. 3. Sensitivity and specificity of the Uriglox and various nitrite tests, including a study of the reliability of the Urnitest as assessed by the screened persons.

Authors:  N Alwall; A Lohi; J Ekenstam
Journal:  Acta Med Scand       Date:  1973-06

5.  Evaluation of Chemstrip LN in a male geriatric population.

Authors:  S M Gelbart; M M Prabhudesai
Journal:  J Am Geriatr Soc       Date:  1988-04       Impact factor: 5.562

  5 in total
  1 in total

1.  A urine analysis method suitable for children's nappies.

Authors:  A Edwards; J van der Voort; R Newcombe; H Thayer; K Verrier Jones
Journal:  J Clin Pathol       Date:  1997-07       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.