Occlusal force and oral tactile sensibility measured in partially edentulous patients with ITI implants.

R Mericske-Stern1, P Assal, E Mericske, W Bürgin.   

Abstract

Maximal occlusal force and oral tactile sensibility were recorded in (1) a group of partially edentulous patients restored with ITI implants supporting fixed prostheses or single crowns and (2) a control group consisting of fully dentate subjects with healthy natural teeth. Maximal occlusal force was measured with a miniature force transducer placed between antagonistic implant/tooth pairs in the test group and antagonistic teeth in the control group. The detection threshold of minimal pressure (ie, passive tactile sensibility) was recorded with dynamometers, and minimal perceived thickness (active tactile sensibility) was assessed using steel foils with a thickness from 100 to 10 microns. Highest maximal occlusal force was measured in fully dentate subjects on second premolars (average 450 N). A significant reduction on the first premolars (300 N) was observed. With fixed prostheses supported by implants, the average value of maximal occlusal force was distinctly lower, about 200 N for first premolars and for molars, and 300 N for second molars. The maximum force was again found on second premolars. The detection threshold of minimal pressure was significantly higher on implants than on natural teeth. The average number of wrong assessments when testing steel foils was 3.2 for antagonistic implant/tooth pairs and 2.6 for natural teeth. The comparison of test sides (with implants) and control sides (without implants) in patients of the test group did not reveal significant differences of measurements. It seems that patterns of oral function depend primarily on the state of dentition, type of prosthodontic restorations, and on psychological aspects, and secondarily on the presence of implants.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7615331

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  15 in total

Review 1.  Osseoperception: An Implant Mediated Sensory Motor Control- A Review.

Authors:  Vishrut Mohan Bhatnagar; Jyoti T Karani; Anshul Khanna; Praveen Badwaik; Ashutosh Pai
Journal:  J Clin Diagn Res       Date:  2015-09-01

2.  Investigating interocclusal perception in tactile teeth sensibility using symmetric and asymmetric analysis.

Authors:  Norbert Enkling; Claudia Nicolay; Stefan Bayer; Regina Mericske-Stern; Karl-Heinz Utz
Journal:  Clin Oral Investig       Date:  2009-10-09       Impact factor: 3.573

3.  In-vitro development of a temporal abutment screw to protect osseointegration in immediate loaded implants.

Authors:  Herminio García-Roncero; Jordi Caballé-Serrano; Jordi Cano-Batalla; Josep Cabratosa-Termes; Oscar Figueras-Álvarez
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

4.  Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis.

Authors:  Luis Gustavo Oliveira de Vasconcellos; Renato Sussumu Nishioka; Luana Marotta Reis de Vasconcellos; Lea Nogueira Braulino de Melo Nishioka
Journal:  J Appl Oral Sci       Date:  2011 Nov-Dec       Impact factor: 2.698

5.  A biomechanical investigation of mandibular molar implants: reproducibility and validity of a finite element analysis model.

Authors:  Miyuki Omori; Yuji Sato; Noboru Kitagawa; Yuta Shimura; Manabu Ito
Journal:  Int J Implant Dent       Date:  2015-04-28

6.  Biomechanical effects of offset placement of dental implants in the edentulous posterior mandible.

Authors:  Yuta Shimura; Yuji Sato; Noboru Kitagawa; Miyuki Omori
Journal:  Int J Implant Dent       Date:  2016-06-17

7.  The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysis.

Authors:  Tsutomu Sugiura; Kazuhiko Yamamoto; Satoshi Horita; Kazuhiro Murakami; Sadami Tsutsumi; Tadaaki Kirita
Journal:  J Periodontal Implant Sci       Date:  2016-06-28       Impact factor: 2.614

8.  Effects of implant tilting and the loading direction on the displacement and micromotion of immediately loaded implants: an in vitro experiment and finite element analysis.

Authors:  Tsutomu Sugiura; Kazuhiko Yamamoto; Satoshi Horita; Kazuhiro Murakami; Sadami Tsutsumi; Tadaaki Kirita
Journal:  J Periodontal Implant Sci       Date:  2017-08-28       Impact factor: 2.614

Review 9.  Complications in implant dentistry.

Authors:  Ayesha Hanif; Saima Qureshi; Zeeshan Sheikh; Haroon Rashid
Journal:  Eur J Dent       Date:  2017 Jan-Mar

10.  Peri-implant biomechanical responses to standard, short-wide, and double mini implants replacing missing molar supporting hybrid ceramic or full-metal crowns under axial and off-axial loading: an in vitro study.

Authors:  Lamiaa Said Elfadaly; Lamiaa Sayed Khairallah; Mona Atteya Al Agroudy
Journal:  Int J Implant Dent       Date:  2017-07-13