Literature DB >> 19816719

Investigating interocclusal perception in tactile teeth sensibility using symmetric and asymmetric analysis.

Norbert Enkling1, Claudia Nicolay, Stefan Bayer, Regina Mericske-Stern, Karl-Heinz Utz.   

Abstract

The purpose of this clinical trial was to determine the active tactile sensibility of natural teeth and to obtain a statistical analysis method fitting a psychometric function through the observed data points. On 68 complete dentulous test persons (34 males, 34 females, mean age 45.9 ± 16.1 years), one pair of healthy natural teeth each was tested: n = 24 anterior teeth and n = 44 posterior teeth. The computer-assisted, randomized measurement was done by having the subjects bite on thin copper foils of different thickness (5-200 µm) inserted between the teeth. The threshold of active tactile sensibility was defined by the 50% value of correct answers. Additionally, the gradient of the sensibility curve and the support area (90-10% value) as a description of the shape of the sensibility curve were calculated. For modeling the sensibility curve, symmetric and asymmetric functions were used. The mean sensibility threshold was 14.2 ± 12.1 µm. The older the subject, the higher the tactile threshold (r = 0.42, p = 0.0006). The support area was 41.8 ± 43.3 µm. The higher the 50% threshold, the smaller the gradient of the curve and the larger the support area. The curves showing the active tactile sensibility of natural teeth demonstrate a tendency towards asymmetry, so that the active tactile sensibility of natural teeth can mathematically best be described by using the asymmetric Weibull function.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19816719     DOI: 10.1007/s00784-009-0348-3

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  26 in total

1.  Measuring, estimating, and understanding the psychometric function: a commentary.

Authors:  S A Klein
Journal:  Percept Psychophys       Date:  2001-11

2.  Converting between measures of slope of the psychometric function.

Authors:  H Strasburger
Journal:  Percept Psychophys       Date:  2001-11

3.  Comparison of oral sensory function in complete denture and implant-supported prosthesis wearers.

Authors:  K S Jang; Y S Kim
Journal:  J Oral Rehabil       Date:  2001-03       Impact factor: 3.837

4.  Vibration sensitivity thresholds: methodological considerations.

Authors:  O Aaserud; J Juntunen; E Matikainen
Journal:  Acta Neurol Scand       Date:  1990-10       Impact factor: 3.209

5.  A multimodal assessment of sensory thresholds in aging.

Authors:  J C Stevens; L A Cruz; L E Marks; S Lakatos
Journal:  J Gerontol B Psychol Sci Soc Sci       Date:  1998-07       Impact factor: 4.077

6.  [The tactile sensitivity of human anterior and lateral teeth with respect to various types of dentures].

Authors:  E Meyer; K Eichner
Journal:  Dtsch Zahnarztl Z       Date:  1987-04

7.  [The interocclusal tactile fine sensitivity of the natural teeth as studied by aluminum oxide particles].

Authors:  K H Utz
Journal:  Dtsch Zahnarztl Z       Date:  1986-03

8.  Age changes in the two-point discrimination threshold in skin innervated by the trigeminal nerve.

Authors:  N Brill; G Tryde; G Morgan; D A Rees
Journal:  J Oral Rehabil       Date:  1974-04       Impact factor: 3.837

9.  Sensory thresholds in discriminating differences in thickness between the teeth, by different degrees of mouth opening.

Authors:  H S Sirilä; P Laine
Journal:  Proc Finn Dent Soc       Date:  1972

10.  In vivo measurements of maximal occlusal force and minimal pressure threshold on overdentures supported by implants or natural roots: a comparative study, Part 1.

Authors:  R Mericske-Stern; J Hofmann; A Wedig; A H Geering
Journal:  Int J Oral Maxillofac Implants       Date:  1993       Impact factor: 2.804

View more
  5 in total

Review 1.  Common risk factors for postoperative pain following the extraction of wisdom teeth.

Authors:  Vahid Rakhshan
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2015-04-23

2.  A study of change in occlusal contacts and force dynamics after fixed prosthetic treatment and after equilibration - Using Tekscan III.

Authors:  Reddy Chaithanya; Suresh Sajjan; A V Rama Raju
Journal:  J Indian Prosthodont Soc       Date:  2019 Jan-Mar

3.  Evaluation of Sensibility Threshold for Interocclusal Thickness of Patients Wearing Complete Dentures.

Authors:  Kujtim Sh Shala; Linda J Dula; Teuta Pustina-Krasniqi; Teuta Bicaj; Enis F Ahmedi; Zana Lila-Krasniqi; Arlinda Tmava-Dragusha
Journal:  Int J Dent       Date:  2017-06-18

4.  Active tactile sensibility of three-unit implant-supported FPDs versus natural dentition.

Authors:  Ramin Negahdari; MohamadAli Ghavimi; Milad Ghanizadeh; Sepideh Bohlouli
Journal:  J Clin Exp Dent       Date:  2019-07-01

Review 5.  Importance of Osseoperception and Tactile Sensibility during Masticatory Function in Different Prosthetic Rehabilitations: A Review.

Authors:  Diego González-Gil; Ibrahim Dib-Zaitum; Javier Flores-Fraile; Joaquín López-Marcos
Journal:  Medicina (Kaunas)       Date:  2022-01-07       Impact factor: 2.430

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.