Literature DB >> 7614789

Dynamic gradient-echo and fat-suppressed spin-echo contrast-enhanced MRI of the breast.

R W Kerslake1, P J Carleton, J N Fox, M J Imrie, A M Cook, J R Read, S J Bowsley, D L Buckley, A Horsman.   

Abstract

PURPOSE: To evaluate heavily T2-weighted, dynamic contrast-enhanced and fat-suppressed magnetic resonance imaging (MRI) of the breast in comparison with conventional imaging and fine needle aspiration cytology (FNAC). PATIENTS AND METHODS: Fifty patients with surgically/pathologically proven breast disease were examined pre-operatively by MRI. The majority, 45 patients, had invasive carcinoma. T1-weighted spin-echo, T2-weighted fast spin-echo (with chemical-shift-selective fat-suppression in 20 cases), rapid dynamic contrast-enhanced gradient-echo and post-contrast fat-suppressed T1-weighted images were obtained. Signal intensity changes during dynamic scanning were assessed qualitatively and quantitatively. Comparison was made with the results of X-ray mammography, ultrasound and fine needle aspiration cytology.
RESULTS: Unenhanced MRI was inadequate for determining the location, extent or nature of most lesions even when fat-suppressed T2-weighted images were obtained. Following contrast injection, there was significantly greater enhancement of invasive carcinomas than normal parenchyma. Invasive carcinomas of ductal and lobular subtypes did not differ significantly in their enhancement profiles. Prominent enhancement of the lesion periphery, which was a feature in 33 out of 50 cases (the majority of which were invasive carcinomas) was not due to central tumour necrosis. In four cases, invasive carcinomas which were clearly visible on early dynamic scans could not be identified on post-contrast fat-suppressed images. Lesions that were more numerous or extensive than had been recognised clinically or mammographically were revealed by MRI in 14 patients, though MRI was no more specific than conventional assessment. Invasion of the chest wall was accurately predicted by MRI in three cases. There was excellent correlation between tumour size shown by MRI and histopathology. FNAC was accurate in predicting the final histological diagnosis except in those cases where samples were unsatisfactory.
CONCLUSIONS: Contrast-enhanced MRI appears useful in the assessment of suspected malignant breast masses, especially in younger women with predominantly glandular breast tissue. Specificity is no better than FNAC but tumour extent and multifocality are more accurately disclosed than by conventional imaging techniques. Contrast-enhanced chemical-shift-selective fat-suppressed images are sub-optimal in a small proportion of cases (particularly where lesions are located posteriorly) and some benign breast disease may appear misleadingly conspicuous on such images. Morphological features and quantification of lesion enhancement during dynamic scanning presently offer only limited prospects for discrimination between various pathologies. Heavily T2-weighted sequences appear of marginal value.

Entities:  

Mesh:

Year:  1995        PMID: 7614789     DOI: 10.1016/s0009-9260(05)83159-9

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  6 in total

1.  Fat suppression strategies in MR imaging of breast cancer at 3.0 T: comparison of the two-point Dixon technique and the frequency selective inversion method.

Authors:  Wakako Kaneko Mikami; Toshiki Kazama; Hirotaka Sato; Hajime Yokota; Takashi Higashide; Takuro Horikoshi; Ken Motoori; Yukimasa Miyazawa; Takeshi Nagashima; Takashi Uno
Journal:  Jpn J Radiol       Date:  2013-06-24       Impact factor: 2.374

2.  Homogenous fat suppression for bilateral breast imaging using independent shims.

Authors:  Misung Han; Charles H Cunningham; John M Pauly; Bruce L Daniel; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2013-07-02       Impact factor: 4.668

3.  Breast cancer abutting the pectoralis major muscle on breast MRI: what are the clinical implications?

Authors:  Kelly S Myers; Erica Stern; Emily B Ambinder; Eniola T Oluyemi
Journal:  Br J Radiol       Date:  2021-01-05       Impact factor: 3.039

4.  Magnetic resonance imaging in size assessment of invasive breast carcinoma with an extensive intraductal component.

Authors:  Arjan P Schouten van der Velden; Carla Boetes; Peter Bult; Theo Wobbes
Journal:  BMC Med Imaging       Date:  2009-04-07       Impact factor: 1.930

5.  Contemporary problems in the surgical management of breast cancer: the surgical/radiological interface.

Authors:  N Beechey-Newman
Journal:  Cancer Imaging       Date:  2000-10-09       Impact factor: 3.909

6.  Can Magnetic Resonance Imaging Replace Mammography and Ultrasonography for the Detection of Breast Lesions?

Authors:  Yeliz Yilmaz; Gulten Sezgin Bener; Kemal Atahan; Nihan Acar; Turan Acar; Haldun Kar; Furkan Tosun; Melek Gokova
Journal:  Cureus       Date:  2020-05-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.