Literature DB >> 23821305

Homogenous fat suppression for bilateral breast imaging using independent shims.

Misung Han1, Charles H Cunningham, John M Pauly, Bruce L Daniel, Brian A Hargreaves.   

Abstract

PURPOSE: To demonstrate the capability of incorporating independent shims into a dual-band spectral-spatial excitation and to compare fat suppression between standard global shims and independent shims for in vivo bilateral breast imaging at 1.5T.
METHODS: A dual-band spectral-spatial excitation pulse was designed by interleaving two flyback spectral-spatial pulses, playing one during positive gradient lobes and the other during negative gradient lobes. Each slab was enabled to have an independent spatial offset, spectral offset, and slab-phase modulation by modulating radiofrequency phase, and independent linear shims were incorporated by playing extra shim gradients. Phantom experiments were performed to demonstrate the functionality of the pulse, and in vivo experiments were performed for 10 healthy volunteers to compare fat suppression between standard shims and independent shims.
RESULTS: The phantom experiments confirmed that the dual-band pulse can provide independent spectral and spatial offsets and linear shims to the two slabs. Independent shims provided qualitatively more homogeneous fat suppression than standard shims in seven out of 10 subjects, with equivalent fat suppression in two of the other three subjects.
CONCLUSION: Incorporating independent shims into the dual-band spectral-spatial excitation can provide homogeneous fat suppression in bilateral breast imaging.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  bilateral breast MRI; dual-band spectral-spatial excitation; fat suppression; independent shims

Mesh:

Year:  2013        PMID: 23821305      PMCID: PMC4085331          DOI: 10.1002/mrm.24803

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Design of improved spectral-spatial pulses for routine clinical use.

Authors:  Y Zur
Journal:  Magn Reson Med       Date:  2000-03       Impact factor: 4.668

2.  Breath-hold water and fat imaging using a dual-echo two-point Dixon technique with an efficient and robust phase-correction algorithm.

Authors:  Jingfei Ma
Journal:  Magn Reson Med       Date:  2004-08       Impact factor: 4.668

3.  Multipoint Dixon technique for water and fat proton and susceptibility imaging.

Authors:  G H Glover
Journal:  J Magn Reson Imaging       Date:  1991 Sep-Oct       Impact factor: 4.813

4.  Simultaneous spatial and spectral selective excitation.

Authors:  C H Meyer; J M Pauly; A Macovski; D G Nishimura
Journal:  Magn Reson Med       Date:  1990-08       Impact factor: 4.668

5.  Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation.

Authors:  D A Feinberg; R Turner; P D Jakab; M von Kienlin
Journal:  Magn Reson Med       Date:  1990-01       Impact factor: 4.668

6.  Simple proton spectroscopic imaging.

Authors:  W T Dixon
Journal:  Radiology       Date:  1984-10       Impact factor: 11.105

7.  1H NMR chemical shift selective (CHESS) imaging.

Authors:  A Haase; J Frahm; W Hänicke; D Matthaei
Journal:  Phys Med Biol       Date:  1985-04       Impact factor: 3.609

8.  Chemical shift selective MR imaging using a whole-body magnet.

Authors:  J Frahm; A Haase; W Hänicke; D Matthaei; H Bomsdorf; T Helzel
Journal:  Radiology       Date:  1985-08       Impact factor: 11.105

9.  MR characterization of suspicious breast lesions with a gadolinium-enhanced TurboFLASH subtraction technique.

Authors:  C Boetes; J O Barentsz; R D Mus; R F van der Sluis; L J van Erning; J H Hendriks; R Holland; S H Ruys
Journal:  Radiology       Date:  1994-12       Impact factor: 11.105

10.  Efficacy of MRI and mammography for breast-cancer screening in women with a familial or genetic predisposition.

Authors:  Mieke Kriege; Cecile T M Brekelmans; Carla Boetes; Peter E Besnard; Harmine M Zonderland; Inge Marie Obdeijn; Radu A Manoliu; Theo Kok; Hans Peterse; Madeleine M A Tilanus-Linthorst; Sara H Muller; Sybren Meijer; Jan C Oosterwijk; Louk V A M Beex; Rob A E M Tollenaar; Harry J de Koning; Emiel J T Rutgers; Jan G M Klijn
Journal:  N Engl J Med       Date:  2004-07-29       Impact factor: 91.245

View more
  2 in total

1.  Bilateral breast MRI by use of dual-source parallel radiofrequency excitation and image-based shimming at 3 Tesla: improvement in homogeneity on fat-suppression imaging.

Authors:  Kinya Ishizaka; Fumi Kato; Satoshi Terae; Suzuko Mito; Noriko Oyama-Manabe; Tamotsu Kamishima; Mitsuhiro Nakanishi; Hiroyuki Sugimori; Hiroyuki Hamaguchi; Hiroki Shirato
Journal:  Radiol Phys Technol       Date:  2014-06-26

2.  Fat Composition Measured by Proton Spectroscopy: A Breast Cancer Tumor Marker?

Authors:  Almir Bitencourt; Varadan Sevilimedu; Elizabeth A Morris; Katja Pinker; Sunitha B Thakur
Journal:  Diagnostics (Basel)       Date:  2021-03-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.