The dependence of EIT images on the assumed initial conductivity distribution: a study of pelvic imaging.

S Meeson1, A L Killingback, B H Blott.   

Abstract

EIT measurements on humans are often made in regions of the body where the conductivity distribution is far from uniform. This paper addresses the problem of deriving accurate quantitative data in one such region: the conductivity changes associated with the accumulation of blood in the pelvic bowl. A computer map of the bone in the pelvic region was constructed, from which an appropriate reconstruction matrix was generated. Both computer simulations and tank tests were performed to assess whether this bone reconstruction matrix produced impedance images with closer fidelity to the measured object than images produced using a reconstruction based on a uniform conductivity distribution. As expected, images produced by the computer simulation indicated that the bone reconstruction matrix produced images of better fidelity than did the uniform reconstruction matrix. However, in the case of the tank data only a moderate improvement was achieved. The reconstruction matrix based on a uniform conductivity distribution was found to produce satisfactory images for both bone and near-uniform objects, but for regions further into the pelvic bowl, where the signal was lower, the uniform reconstruction matrix was less satisfactory.

Entities:  

Mesh:

Year:  1995        PMID: 7610119     DOI: 10.1088/0031-9155/40/4/010

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  Electrical impedance tomography reconstruction algorithm based on general inversion theory and finite element method.

Authors:  T Mengxing; D Xiuzhen; Q Mingxin; F Feng; S Xuetao; Y Fusheng
Journal:  Med Biol Eng Comput       Date:  1998-07       Impact factor: 2.602

2.  Quantification of intraventricular hemorrhage with electrical impedance tomography using a spherical model.

Authors:  T Tang; R J Sadleir
Journal:  Physiol Meas       Date:  2011-06-07       Impact factor: 2.833

3.  A robust current pattern for the detection of intraventricular hemorrhage in neonates using electrical impedance tomography.

Authors:  T Tang; Sungho Oh; R J Sadleir
Journal:  Ann Biomed Eng       Date:  2010-03-18       Impact factor: 3.934

4.  Normalization of a spatially variant image reconstruction problem in electrical impedance tomography using system blurring properties.

Authors:  Sungho Oh; Te Tang; A S Tucker; R J Sadleir
Journal:  Physiol Meas       Date:  2009-02-06       Impact factor: 2.833

5.  A 3D visualization method for bladder filling examination based on EIT.

Authors:  Wei He; Peng Ran; Zheng Xu; Bing Li; Song-nong Li
Journal:  Comput Math Methods Med       Date:  2012-12-31       Impact factor: 2.238

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.