Literature DB >> 7601654

Blue light-emitting diode built-in contact lens electrode can record human S-cone electroretinogram.

M Horiguchi1, Y Miyake, M Kondo, S Suzuki, A Tanikawa, H M Koo.   

Abstract

PURPOSE: To develop a contact lens electrode with a built-in blue light-emitting diode (LED) to record the electroretinogram from short-wave sensitive-cone (S-cone) electroretinogram (ERG) in humans.
METHODS: The ERG was recorded using the blue LED (450 nm) built-in electrode under a yellow background illumination from a slide projector in five normal subjects, a patient with blue cone monochromatism, and a patient with fundus albipunctatus. For comparison, the ERG was also recorded using a yellow LED (566 nm) built-in electrode under the same background illumination in the normal subjects.
RESULTS: The amplitude and the peak time of the b-wave recorded with 3-Hz blue stimuli were 5.1 to 12.4 microV and 63 to 68 msec, respectively in normal subjects, 7.3 microV and 65 msec in the patient with blue cone monochromatism, and 11.4 microV and 65 msec in the patient with fundus albipunctatus. Normal subjects responded to neither 30-Hz blue stimuli nor 3-Hz yellow stimuli.
CONCLUSIONS: Results indicate that the b-wave recorded with 3-Hz blue stimuli is elicited from the S-cone system. This simple technique is useful for testing the human blue cone system.

Entities:  

Mesh:

Year:  1995        PMID: 7601654

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  6 in total

1.  Electroretinography of short-wavelength-sensitive cones with a LED built-in electrode and its normal values.

Authors:  Kazuki Kuniyoshi; Naoki Uno; Motohiro Irifune; Yoshikazu Shimomura
Journal:  Doc Ophthalmol       Date:  2003-05       Impact factor: 2.379

2.  Spectral characteristics of light sources for S-cone stimulation.

Authors:  F Schlegelmilch; R Nolte; K Schellhorn; P Husar; G Henning; R P Tornow
Journal:  Doc Ophthalmol       Date:  2002-11       Impact factor: 2.379

3.  Built-in LED contact lens electrode for S-cone electroretinographic recordings.

Authors:  Mieko Tsuruoka; Shuichi Yamamoto; Kazuha Ogata; Masanori Hayashi
Journal:  Doc Ophthalmol       Date:  2004-01       Impact factor: 2.379

4.  Electroretinographic evaluation of the retinal S-cone system.

Authors:  Maja Sustar; Marko Hawlina; Jelka Brecelj
Journal:  Doc Ophthalmol       Date:  2011-11-27       Impact factor: 2.379

5.  ISCEV extended protocol for the S-cone ERG.

Authors:  Ido Perlman; Mineo Kondo; Enid Chelva; Anthony G Robson; Graham E Holder
Journal:  Doc Ophthalmol       Date:  2019-11-20       Impact factor: 2.379

6.  Clinical S-cone ERG recording with a commercial hand-held full-field stimulator.

Authors:  Michael F Marmor; Lorella Cabael; Shefalee Shukla; John C Hwang; Mira Marcus
Journal:  Doc Ophthalmol       Date:  2004-07       Impact factor: 2.379

  6 in total