Literature DB >> 7600750

Effect of ambient temperature and humidity on performance of blood glucose meters.

J M King1, C A Eigenmann, S Colagiuri.   

Abstract

The accuracy of four blood glucose meters (Accutrend, ExacTech Companion, Medisense Companion 2, and Glucometer III) was tested at temperatures ranging from 4 to 44 degrees C (control solutions) and 8 degrees C, 24 degrees C, and 36 degrees C (venous blood) and at humidities of 60% and 80%. Low and high temperatures resulted in a number of statistically significant changes in glucose readings with all meters. However, Accutrend, Medisense Companion 2, and Glucometer III were 100% clinically accurate at all temperatures. With the ExacTech Companion, only 70.8% of control solution and 55.6% of venous blood results were clinically accurate. The main errors were: (1) cold temperatures lowered the result so that euglycaemic levels erroneously read in the hypoglycaemic range and hyperglycaemic levels gave a better than actual result and (2) hot temperatures increased the result whereby hypoglycaemic levels falsely gave a euglycaemic result. Weather conditions at which blood glucose meters may be operated can affect results and potentially lead to errors in clinical decisions.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7600750     DOI: 10.1111/j.1464-5491.1995.tb00488.x

Source DB:  PubMed          Journal:  Diabet Med        ISSN: 0742-3071            Impact factor:   4.359


  6 in total

Review 1.  Geoenvironmental diabetology.

Authors:  Curtiss B Cook; Kay E Wellik; Margaret Fowke
Journal:  J Diabetes Sci Technol       Date:  2011-07-01

2.  The Effects of Temperature and Relative Humidity on Point-of-Care Glucose Measurements in Hospital Practice in a Tropical Clinical Setting.

Authors:  Busadee Pratumvinit; Nattakom Charoenkoop; Soamsiri Niwattisaiwong; Gerald J Kost; Panutsaya Tientadakul
Journal:  J Diabetes Sci Technol       Date:  2016-08-22

3.  Increases in whole blood glucose measurements using optically based self-monitoring of blood glucose analyzers due to extreme Canadian winters.

Authors:  George C Cembrowski; Barbara Smith; Ellen M O'Malley
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

Review 4.  Challenges to glycemic measurement in the perioperative and critically ill patient: a review.

Authors:  Andrew D Pitkin; Mark J Rice
Journal:  J Diabetes Sci Technol       Date:  2009-11-01

Review 5.  Glucose homeostasis during short-term and prolonged exposure to high altitudes.

Authors:  Orison O Woolcott; Marilyn Ader; Richard N Bergman
Journal:  Endocr Rev       Date:  2015-02-12       Impact factor: 19.871

6.  Obtaining accurate glucose measurements from wild animals under field conditions: comparing a hand held glucometer with a standard laboratory technique in grey seals.

Authors:  Kimberley A Bennett; Lucy M Turner; Sebastian Millward; Simon E W Moss; Ailsa J Hall
Journal:  Conserv Physiol       Date:  2017-02-27       Impact factor: 3.079

  6 in total