Detection of errors in individual patients in radiotherapy by systematic in vivo dosimetry.

A Noel1, P Aletti, P Bey, L Malissard.   

Abstract

We report 5 years of systematic measurements of the dose delivered to each patient undergoing radiotherapy treatment with photon beams in order to detect any systematic error that may have escaped the different checks performed at each step of planning and calculation prior to the first treatment session, or may have arisen during the set-up or the treatment delivery. For each patient the target-absorbed dose is derived from the entrance and exit doses measured by silicon diodes, on the beam axis at the patient's skin. Depending on the discrepancies observed between the measured and expected doses we have set decision levels for the corrective actions to be taken. In addition these measurements allow us to obtain information on the overall accuracy or on the quality of a specific treatment. During 5 years, 7519 patients have been measured and 79 errors were detected. Half could have induced a variation of over 10% in the dose delivered. Seventy-eight out of 79 errors were of human origin. As part of an overall quality assurance programme, it is of the utmost importance to check the dose delivered for each patient undergoing radiotherapy treatment in order to avoid systematic underdosing or overdosing.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7597213     DOI: 10.1016/0167-8140(94)01503-u

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  9 in total

1.  Verification of Entrance Dose Measurements with Thermoluminescent Dosimeters in Conventional Radiotherapy Procedures Delivered with Co-60 Teletherapy Machine.

Authors:  O B Evwierhurhoma; Z A Ibitoye; C A Ojieh; Jtk Duncan
Journal:  Ann Med Health Sci Res       Date:  2015 Nov-Dec

2.  In vivo dosimetry in UK external beam radiotherapy: current and future usage.

Authors:  Niall D MacDougall; Michael Graveling; Vibeke N Hansen; Kevin Brownsword; Andrew Morgan
Journal:  Br J Radiol       Date:  2017-02-16       Impact factor: 3.039

3.  Initial characterization of a gel patch dosimeter for in vivo dosimetry.

Authors:  C Matrosic; W Culberson; B Rosen; E Madsen; G Frank; B Bednarz
Journal:  Phys Med Biol       Date:  2016-04-18       Impact factor: 3.609

4.  Comparing treatment uncertainty for ultra- vs. standard-hypofractionated breast radiation therapy based on in-vivo dosimetry.

Authors:  Yawo A C Fiagan; Evy Bossuyt; Melanie Machiels; Daan Nevens; Charlotte Billiet; Philip Poortmans; Thierry Gevaert; Dirk Verellen
Journal:  Phys Imaging Radiat Oncol       Date:  2022-05-13

5.  Evaluation of safety in a radiation oncology setting using failure mode and effects analysis.

Authors:  Eric C Ford; Ray Gaudette; Lee Myers; Bruce Vanderver; Lilly Engineer; Richard Zellars; Danny Y Song; John Wong; Theodore L Deweese
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-05-04       Impact factor: 7.038

6.  Evaluation of automated pre-treatment and transit in-vivo dosimetry in radiotherapy using empirically determined parameters.

Authors:  Evy Bossuyt; Reinhilde Weytjens; Daan Nevens; Sarah De Vos; Dirk Verellen
Journal:  Phys Imaging Radiat Oncol       Date:  2020-11-09

7.  Pre-clinical and clinical evaluation of the HYPERSCINT plastic scintillation dosimetry research platform for in vivo dosimetry during radiotherapy.

Authors:  Imke Schoepper; Sonja Dieterich; Earl Alonzo Trestrail; Michael Sean Kent
Journal:  J Appl Clin Med Phys       Date:  2022-02-21       Impact factor: 2.102

8.  Characterization of GafChromic EBT2 film dose measurements using a tissue-equivalent water phantom for a Theratron® Equinox Cobalt-60 teletherapy machine.

Authors:  Daniel Akwei Addo; Elsie Effah Kaufmann; Samuel Nii Tagoe; Augustine Kwame Kyere
Journal:  PLoS One       Date:  2022-08-19       Impact factor: 3.752

9.  Evaluation of target dose based on water-equivalent thickness in external beam radiotherapy.

Authors:  Behnaz Ghanbar Moghaddam; Masoud Vahabi-Moghaddam; Alireza Sadremomtaz
Journal:  J Med Phys       Date:  2013-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.