Combined use of the esophageal-tracheal Combitube with a colorimetric carbon dioxide detector for emergency intubation/ventilation.

B D Butler1, T Little, S Drtil.   

Abstract

OBJECTIVE: The esophageal-tracheal Combitube (Sheridan, Inc., Argyle, NY) is a unique double lumen tube that has been introduced as an emergency intubation device. Since it is placed blindly, proper use requires determination of which lumen can be successfully used for ventilation. The Easycap (Nellcor, Inc., Pleasanton, CA) is a colorimetric carbon dioxide detector that reacts with exhaled gas to indicate proper tracheal tube location. The purpose of this study was to determine if the Easycap can be used to identify which Combitube lumen is patent to the trachea after blind placement in dogs. METHODS AND
RESULTS: The study was conducted using 8 anesthetized dogs. In each of 15 blind insertions of the Combitube, the Easycap device responded appropriately by changing color from purple to yellow when connected to the lumen communicating with the trachea. When the Easycap device was connected to the alternate lumen, no color change was appropriately observed in 9 out of 15 cases (60%) after 6 breaths; in 4 of the remaining 6 (87%, total), no color change was noted after 12 breaths. In the 2 remaining cases, the color change indicated the need of further verification of the tube location. In separate experiments, 10 direct tracheal and esophageal insertions of the Combitube were correctly verified by the appropriate Easycap color change.
CONCLUSIONS: Our results suggest that the Easycap device may be useful with the Combitube, although human data are required.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7595687     DOI: 10.1007/BF01616989

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  17 in total

1.  Reliability of capnography in identifying esophageal intubation with carbonated beverage or antacid in the stomach.

Authors:  S T Sum Ping; M P Mehta; T Symreng
Journal:  Anesth Analg       Date:  1991-09       Impact factor: 5.108

2.  Colorimetric end-tidal carbon dioxide monitoring for tracheal intubation.

Authors:  J S Goldberg; P R Rawle; J L Zehnder; R N Sladen
Journal:  Anesth Analg       Date:  1990-02       Impact factor: 5.108

3.  Use of a disposable carbon dioxide detector with emergency intubation in a hyperbaric chamber.

Authors:  S R Larson; T Sutton; S Koch; B D Butler
Journal:  Aviat Space Environ Med       Date:  1993-12

4.  Controversies in out-of-hospital emergency airway control: esophageal obstruction or endotracheal intubation?

Authors:  R D White
Journal:  Ann Emerg Med       Date:  1984-09       Impact factor: 5.721

5.  The esophageal obturator airway: a clinical comparison to ventilation with a mask and oropharyngeal airway.

Authors:  T K Bryson; J L Benumof; C F Ward
Journal:  Chest       Date:  1978-11       Impact factor: 9.410

6.  Verification of endotracheal tube placement with colorimetric end-tidal CO2 detection.

Authors:  B A MacLeod; M B Heller; J Gerard; D M Yealy; J J Menegazzi
Journal:  Ann Emerg Med       Date:  1991-03       Impact factor: 5.721

7.  A disposable end-tidal CO2 detector to verify endotracheal intubation.

Authors:  W R Anton; R W Gordon; T M Jordan; K L Posner; F W Cheney
Journal:  Ann Emerg Med       Date:  1991-03       Impact factor: 5.721

8.  Mechanical ventilation with the esophageal tracheal combitube (ETC) in the intensive care unit.

Authors:  M Frass; R Frenzer; G Mayer; R Popovic; C Leithner
Journal:  Arch Emerg Med       Date:  1987-12

9.  Capnographic waveforms in esophageal intubation: effect of carbonated beverages.

Authors:  A R Garnett; C A Gervin; A S Gervin
Journal:  Ann Emerg Med       Date:  1989-04       Impact factor: 5.721

10.  Clinical utility of a colorimetric end-tidal CO2 detector in cardiopulmonary resuscitation and emergency intubation.

Authors:  A J Varon; J Morrina; J M Civetta
Journal:  J Clin Monit       Date:  1991-10
View more
  2 in total

1.  Esophageal-tracheal Combitube, colorimetric carbon dioxide detection, and the esophageal detector device.

Authors:  W H Maleck; K P Koetter
Journal:  J Clin Monit       Date:  1996-03

2.  The comparison of capnography and epigastric auscultation to assess the accuracy of nasogastric tube placement in intensive care unit patients.

Authors:  Elahe Heidarzadi; Rostam Jalali; Behzad Hemmatpoor; Nader Salari
Journal:  BMC Gastroenterol       Date:  2020-06-22       Impact factor: 3.067

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.