Colorimetric end-tidal carbon dioxide monitoring for tracheal intubation.

J S Goldberg1, P R Rawle, J L Zehnder, R N Sladen.   

Abstract

We evaluated a colorimetric end-tidal carbon dioxide (ETCO2) detector (FEF end-tidal carbon dioxide detector, Fenem, New York, N.Y.) during 62 intubations in anesthetized patients who were hemodynamically stable. The intubations were performed during a drill that simulates difficult tracheal intubation and therefore is associated with an increased risk of esophageal intubation. Each intubation attempt was monitored by two anesthesiologists and a research assistant who together used chest auscultation, colorimetric ETCO2, and capnography to confirm tracheal intubation and detect esophageal intubation. The reliability of the monitors was compared with capnography. Colorimetric ETCO2 confirmed tracheal intubations and detected esophageal intubations 100% of the time, as judged by capnography. There were no false-positive or false-negative decisions based on endotracheal tube position; however, one equivocal color change occurred, which was caused by failure to inflate the endotracheal tube cuff. Colorimetric ETCO2 monitoring confirmed tracheal intubation more rapidly than did chest auscultation (P less than 0.001) or capnography (P less than 0.05), and detected esophageal intubation more rapidly than did chest auscultation (P less than 0.05) and as rapidly as capnography did. Confirmation of tracheal intubation was achieved earlier than detection of esophageal intubation with all three monitors (P less than 0.05). We conclude that colorimetric ETCO2 monitoring is a safe, reliable, rapid, simple, and portable method for determining endotracheal tube position for patients who are hemodynamically stable and should be recommended where capnography is not available.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2105671     DOI: 10.1213/00000539-199002000-00011

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  13 in total

Review 1.  Emergency management of the airway outside the operating room.

Authors:  D L Bogdonoff; D J Stone
Journal:  Can J Anaesth       Date:  1992-12       Impact factor: 5.063

Review 2.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

3.  End tidal carbon dioxide detector for monitoring cardiopulmonary resuscitation.

Authors:  J D Muir; P B Randalls; G B Smith
Journal:  BMJ       Date:  1990-07-07

4.  A simple, disposable end-tidal carbon dioxide detector.

Authors:  M Rosenberg; C S Block
Journal:  Anesth Prog       Date:  1991 Jan-Feb

5.  Colorimetric end-tidal carbon dioxide monitoring during transfer of intubated children.

Authors:  D Higgins; E T Forrest; A Lloyd-Thomas
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

6.  Sensitivity of a disposable end-tidal carbon dioxide detector.

Authors:  B R Jones; M J Dorsey
Journal:  J Clin Monit       Date:  1991-07

7.  A system of classification for the clinical applications of capnography.

Authors:  Naveen Eipe; Jordan Tarshis
Journal:  J Clin Monit Comput       Date:  2007-10-09       Impact factor: 2.502

8.  Combined use of the esophageal-tracheal Combitube with a colorimetric carbon dioxide detector for emergency intubation/ventilation.

Authors:  B D Butler; T Little; S Drtil
Journal:  J Clin Monit       Date:  1995-09

Review 9.  Physiology and pathophysiology at high altitude: considerations for the anesthesiologist.

Authors:  Kay B Leissner; Feroze U Mahmood
Journal:  J Anesth       Date:  2009-11-18       Impact factor: 2.078

10.  Prehospital determination of tracheal tube placement in severe head injury.

Authors:  S Grmec; S Mally
Journal:  Emerg Med J       Date:  2004-07       Impact factor: 2.740