Literature DB >> 7593115

In vivo corrosion of cobalt-chromium and titanium wear particles.

B F Shahgaldi1, F W Heatley, A Dewar, B Corrin.   

Abstract

Tissue reaction to wear particles from metal implants may play a major role in the aseptic loosening of implants. We used electron microprobe elemental analysis to determine the chemical composition of wear particles embedded in the soft tissues around hip and knee implants from 11 patients at revision surgery for aseptic loosening. The implants were made of cobalt-chromium-molybdenum alloy or titanium-aluminium-vanadium alloy. Histological examination showed a widespread giant-cell reaction to the particles. Elemental analysis showed that the chemical composition of the particles was different from that of the implanted alloys: cobalt and titanium were reduced, often down to zero, whereas chromium and aluminium persisted. Our findings indicate that corrosion is continually changing the shape, size and chemical composition of the implanted alloy. This may alter the biochemical environment of the tissue surrounding an implant to favour bone resorption.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7593115

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  12 in total

Review 1.  New insights into wear and biological effects of metal-on-metal bearings.

Authors:  Isabelle Catelas; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-05       Impact factor: 5.284

2.  Increasing both CoCrMo-alloy particle size and surface irregularity induces increased macrophage inflammasome activation in vitro potentially through lysosomal destabilization mechanisms.

Authors:  Marco S Caicedo; Lauryn Samelko; Kyron McAllister; Joshua J Jacobs; Nadim J Hallab
Journal:  J Orthop Res       Date:  2013-06-21       Impact factor: 3.494

3.  Release of elements from retrieved maxillofacial plates and screws.

Authors:  C Bertoldi; J M Pradelli; U Consolo; D Zaffe
Journal:  J Mater Sci Mater Med       Date:  2005-09       Impact factor: 3.896

4.  The cytotoxicity of chromium in osteoblasts: effects on macromolecular synthesis.

Authors:  J Ning; C Henderson; M H Grant
Journal:  J Mater Sci Mater Med       Date:  2002-01       Impact factor: 3.896

5.  Determination of metallic traces in kidneys, livers, lungs and spleens of rats with metallic implants after a long implantation time.

Authors:  Juan Carlos Rubio; Maria Cristina Garcia-Alonso; Concepcion Alonso; Miguel Angel Alobera; Celia Clemente; Luis Munuera; Maria Lorenza Escudero
Journal:  J Mater Sci Mater Med       Date:  2007-07-03       Impact factor: 3.896

6.  CoCrMo metal-on-metal hip replacements.

Authors:  Yifeng Liao; Emily Hoffman; Markus Wimmer; Alfons Fischer; Joshua Jacobs; Laurence Marks
Journal:  Phys Chem Chem Phys       Date:  2013-01-21       Impact factor: 3.676

7.  Titanium Implant Osseointegration Problems with Alternate Solutions Using Epoxy/Carbon-Fiber-Reinforced Composite.

Authors:  Richard C Petersen
Journal:  Metals (Basel)       Date:  2014-12       Impact factor: 2.351

8.  Improvement of Cr-Co-Mo Membrane Surface Used as Barrier for Bone Regeneration through UV Photofunctionalization: An In Vitro Study.

Authors:  Oscar Decco; Jésica Zuchuat; Nicolás Farkas
Journal:  Materials (Basel)       Date:  2017-07-21       Impact factor: 3.623

9.  Taper Corrosion and Adverse Local Tissue Reactions in Patients with a Modular Knee Prosthesis.

Authors:  Tom Christiner; Moreica B Pabbruwe; Alan M Kop; Jeremy Parry; Gavin Clark; Dermot Collopy
Journal:  JB JS Open Access       Date:  2018-11-13

10.  In vitro testing of femoral impaction grafting with porous titanium particles: a pilot study.

Authors:  René Aquarius; Luc Walschot; Pieter Buma; Berend Willem Schreurs; Nico Verdonschot
Journal:  Clin Orthop Relat Res       Date:  2009-01-13       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.