Literature DB >> 7593058

Use of an articulated external fixator for fractures of the tibial plafond.

J L Marsh1, S Bonar, J V Nepola, T A Decoster, S R Hurwitz.   

Abstract

We performed a prospective study of forty-nine displaced fractures of the tibial plafond in forty-eight patients managed, at three centers, with an articulated external fixator placed medially across the ankle joint. Forty ankles had interfragmental screw fixation of a reduced articular fracture, and fourteen ankles had bone-grafting. The average duration of external fixation was twelve weeks. All of the fractures healed (one after delayed bone-grafting). There were no infections in any of the operative or traumatic wounds over the tibia. Two wound infections over the fibula resolved with treatment. Eight patients were managed with antibiotics for a pin-site infection, and two patients had curettage and débridement of a pin site in the hindfoot after removal of the fixator. Thirty patients (thirty-one ankles) completed two-year data sheets at an average of thirty months after the injury. The average ankle score was 67 points. Twenty-one patients had grade-0 or 1 osteoarthrosis and nine had grade-2 or 3. One ankle had been treated with an arthrodesis. These data suggest that the prevalence of early complications associated with severe fractures of the tibial plafond and their treatment can be decreased with use of an articulated external fixator combined with limited internal fixation. We concluded that this technique of external fixation is a satisfactory technique for the treatment of these fractures.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7593058     DOI: 10.2106/00004623-199510000-00004

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  21 in total

1.  Outcome of 28 open pilon fractures with injury severity-based fixation.

Authors:  Jonathan R Danoff; Comron Saifi; David C Goodspeed; J Spence Reid
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-09-26

2.  The effects of silver coated external fixation pins.

Authors:  Lisa M Coester; James V Nepola; Judy Allen; J Lawrence Marsh
Journal:  Iowa Orthop J       Date:  2006

Review 3.  Basic science of intra-articular fractures and posttraumatic osteoarthritis.

Authors:  Todd O McKinley; Joseph Borrelli; Darryl D D'Lima; Bridgette D Furman; Peter V Giannoudis
Journal:  J Orthop Trauma       Date:  2010-09       Impact factor: 2.512

4.  Staged protocol in treatment of open distal tibia fracture: using lateral MIPO.

Authors:  Oog Jin Sohn; Dong Hwa Kang
Journal:  Clin Orthop Surg       Date:  2011-02-15

5.  Fracture healing following high energy tibial trauma: Ilizarov versus Taylor Spatial Frame.

Authors:  C U Menakaya; A S Rigby; Y Hadland; E Barron; H Sharma
Journal:  Ann R Coll Surg Engl       Date:  2014-03       Impact factor: 1.891

6.  The sequential recovery of health status after tibial plafond fractures.

Authors:  J Lawrence Marsh; Todd McKinley; Douglas Dirschl; Andrew Pick; Geoffrey Haft; Donald D Anderson; Thomas Brown
Journal:  J Orthop Trauma       Date:  2010-08       Impact factor: 2.512

7.  Is elevated contact stress predictive of post-traumatic osteoarthritis for imprecisely reduced tibial plafond fractures?

Authors:  Donald D Anderson; Christopher Van Hofwegen; J Lawrence Marsh; Thomas D Brown
Journal:  J Orthop Res       Date:  2011-01       Impact factor: 3.494

8.  The pathomechanical etiology of post-traumatic osteoarthritis following intraarticular fractures.

Authors:  Donald D Anderson; J Lawrence Marsh; Thomas D Brown
Journal:  Iowa Orthop J       Date:  2011

9.  Staged external and internal locked plating for open distal tibial fractures.

Authors:  Ching-Hou Ma; Shang-Won Yu; Yuan-Kun Tu; Cheng-Yo Yen; James Jih-Hsi Yeh; Chin-Hsien Wu
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

10.  Minimally invasive locked plating of distal tibia fractures is safe and effective.

Authors:  Mario Ronga; Umile Giuseppe Longo; Nicola Maffulli
Journal:  Clin Orthop Relat Res       Date:  2009-07-30       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.