Literature DB >> 7575967

Load fatigue of teeth restored with cast posts and cores and complete crowns.

W J Libman1, J I Nicholls.   

Abstract

Twenty-five extracted human central incisors were divided into five groups and prepared for complete cast crowns. Test teeth had cast dowel cores fabricated with the ferrule height varying from 0.5 to 2.0 mm in 0.5-mm increments. The five control teeth did not have cast dowel cores. A 4.0-kg load was applied to each of the restored teeth at an angle of 135 degrees to the long axis of each tooth. This load was applied cyclically at a rate of 72 cycles per minute. The load application point was predetermined by a waxing jig that was used to wax all crowns. The primary variable was the ferrule length. The independent variable was the number of load cycles required to create preliminary failure. Preliminary failure was defined here as the loss of the sealing cement layer between crown and tooth. An electrical resistance strain gauge was used to provide evidence of preliminary failure. The results of this study showed that the 0.5 mm and 1.0 mm ferrule lengths failed at a significantly lower number of cycles than the 1.5 mm and 2.0 mm ferrule lengths and control teeth.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7575967

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  28 in total

1.  Effect of the ferrule on fracture resistance of teeth restored with prefabricated posts and composite cores.

Authors:  Annet Kutesa-Mutebi; Yusuf I Osman
Journal:  Afr Health Sci       Date:  2004-08       Impact factor: 0.927

2.  Resistance to cyclic loading of teeth restored with posts.

Authors:  A Sahafi; A Peutzfeldt; G Ravnholt; E Asmussen; K Gotfredsen
Journal:  Clin Oral Investig       Date:  2005-03-04       Impact factor: 3.573

3.  Influence of type of luting cement used with all-ceramic crowns on load capability of post-restored endodontically treated maxillary central incisors.

Authors:  Anja Preuss; Martin Rosentritt; Roland Frankenberger; Florian Beuer; Michael Naumann
Journal:  Clin Oral Investig       Date:  2007-11-27       Impact factor: 3.573

4.  Comparative evaluation of fracture resistance of various post systems using different luting agents under tangential loading.

Authors:  Rajnish Aggarwal; Swati Gupta; Amrit Tandan; Narendra Kumar Gupta; Ravi Dwivedi; Renu Aggarwal
Journal:  J Oral Biol Craniofac Res       Date:  2013-04-17

5.  Effect of Different Ferrule Length on Fracture Resistance of Endodontically Treated Teeth: An In vitro Study.

Authors:  Sushil Kar; Arvind Tripathi; Chavi Trivedi
Journal:  J Clin Diagn Res       Date:  2017-04-01

6.  Minimally invasive endodontics: challenging prevailing paradigms.

Authors:  A H Gluskin; C I Peters; O A Peters
Journal:  Br Dent J       Date:  2014-03       Impact factor: 1.626

7.  Fracture resistance of endodontically treated teeth restored with a bulkfill flowable material and a resin composite.

Authors:  Almira Isufi; Gianluca Plotino; Nicola Maria Grande; Pietro Ioppolo; Luca Testarelli; Rossella Bedini; Dina Al-Sudani; Gianluca Gambarini
Journal:  Ann Stomatol (Roma)       Date:  2016-07-19

8.  An In Vitro Study on the Effects of Post-Core Design and Ferrule on the Fracture Resistance of Endodontically Treated Maxillary Central Incisors.

Authors:  S Sreedevi; R Sanjeev; Rekha Raghavan; Anna Abraham; T Rajamani; Girish Kumar Govind
Journal:  J Int Oral Health       Date:  2015-08

9.  Insufficient evidence on whether to restore root-filled teeth with single crowns or routine fillings.

Authors:  David McReynolds; Brett Duane
Journal:  Evid Based Dent       Date:  2016-06

10.  In vitro evaluation of ferrule effect and depth of post insertion on fracture resistance of fiber posts.

Authors:  R Schiavetti; G Sannino
Journal:  Comput Math Methods Med       Date:  2012-12-02       Impact factor: 2.238

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.