Literature DB >> 7574966

Embolization of biologic glue during repair of aortic dissection.

T Carrel1, M Maurer, T Tkebuchava, U Niederhäuser, J Schneider, M I Turina.   

Abstract

A 72-year-old patient was operated on because of an acute type A aortic dissection with the primary entry located in the aortic arch and with retrograde involvement of the ascending aorta. Complete replacement of the aortic arch and the ascending aorta was performed after the dissected aortic layers had been readapted and sealed with gelatin-resorcin-formaldehyde biologic glue. Postoperative neurologic status was judged to be normal. The patient died 3 weeks postoperatively of septic shock. Postmortem examination of the brain revealed several small lesions, and microscopy showed very small particles of polymerized glue in the afferent vessels of ischemic cerebral and meningeal regions.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7574966     DOI: 10.1016/0003-4975(95)97585-b

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

1.  BioGlue in 2011: what is its role in cardiac surgery?

Authors:  Castigliano M Bhamidipati; Joseph S Coselli; Scott A LeMaire
Journal:  J Extra Corpor Technol       Date:  2012-03

2.  Effectiveness of a new inflatable balloon device for gluing dissected layers in an experimental model of aortic dissection.

Authors:  Necmettin Colak; Yunus Nazli; Mehmet Fatih Alpay; Ismail Olgun Akkaya; Omer Nuri Aksoy; Sukran Akgedik; Omer Cakir
Journal:  Exp Clin Cardiol       Date:  2013

3.  Hemostatic modifications of the Bentall procedure: imbricated proximal suture and fibrin sealant reduce postoperative morbidity and mortality rates.

Authors:  Alessandro Della Corte; Francesco Baldascino; Francesca La Marca; Michelangelo Scardone; Gianantonio Nappi; Mariano Cefarelli; Luca S De Santo; Paolo Pepino; Maurizio Cotrufo; Marisa De Feo
Journal:  Tex Heart Inst J       Date:  2012

4.  Cerebral embolic shower secondary to BioGlue use in triple valve surgery.

Authors:  Venkatesa Kumar Anakaputhur Rajan; Srikanth Kasturi; Niranjan Soundararajan; Priyankar Sinha
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2022-03-30

5.  BioGlue cerebral embolism following acute type A aortic dissection repair.

Authors:  Manabu Yamasaki; Kohei Abe; Ryota Nakamura; Rihito Tamaki; Hiroyasu Misumi
Journal:  J Cardiol Cases       Date:  2022-07-16

6.  Delayed Pulmonary Artery Rupture after Using BioGlue in Cardiac Surgery.

Authors:  Wongi Woo; Soonchang Hong; Tae-Hoon Kim; Min-Young Baek; Suk-Won Song
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2017-12-05
  6 in total