Literature DB >> 7567260

Comparison of helical and conventional chest CT in the uncooperative pediatric patient.

T D Cox1, K S White, E Weinberger, E L Effmann.   

Abstract

The objective of this study was to compare the quality of conventional and helical computed tomography (CT) images in children unable to breath-hold. Sixteen patients (age range 1.1-7.5 years) underwent both conventional and helical chest CT on a General Electric HiSpeed Advantage scanner at a mean study interval of 3.8 months. Conventional 0.6-s scans were reconstructed with standard algorithm while 1.0-s helical studies were reconstructed with standard and bone algorithms. Three blinded observers retrospectively evaluated the images. There was no significant difference in motion, image sharpness and anatomic resolution for helical and conventional scans reconstructed with standard algorithm. Furthermore, image sharpness (P < 0.001) and visibility of bronchi (P < 0.001) were improved when helical images were reconstructed with bone algorithm. We conclude that motion artifact severity, image sharpness and anatomic resolution for helical and conventional 0.6-s chest CT are similar when the images are reconstructed with an identical algorithm. Helical CT may be preferable because of the faster examination times and the ability to reconstruct overlapping images as an adjunct for problem solving. Also, with the scanner used, bone algorithm reconstruction can be employed to improve image sharpness and anatomic resolution.

Entities:  

Mesh:

Year:  1995        PMID: 7567260     DOI: 10.1007/BF02021699

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  12 in total

1.  Low-dose high-resolution CT of lung parenchyma.

Authors:  C V Zwirewich; J R Mayo; N L Müller
Journal:  Radiology       Date:  1991-08       Impact factor: 11.105

2.  Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.

Authors:  W A Kalender; W Seissler; E Klotz; P Vock
Journal:  Radiology       Date:  1990-07       Impact factor: 11.105

Review 3.  CT evaluation for pulmonary metastases in patients with extrathoracic malignancy.

Authors:  S D Davis
Journal:  Radiology       Date:  1991-07       Impact factor: 11.105

4.  High-spatial-frequency (bone) algorithm improves quality of standard CT of the thorax.

Authors:  C V Zwirewich; B Terriff; N L Müller
Journal:  AJR Am J Roentgenol       Date:  1989-12       Impact factor: 3.959

5.  Ultrafast computed tomography for infants and children.

Authors:  R C Brasch
Journal:  Radiol Clin North Am       Date:  1988-03       Impact factor: 2.303

6.  Pulmonary nodule: evaluation with spiral volumetric CT.

Authors:  P Costello; W Anderson; D Blume
Journal:  Radiology       Date:  1991-06       Impact factor: 11.105

7.  Paediatric pulmonary nodules: a comparison of computed tomography, thoracotomy findings and histology.

Authors:  P L Robertson; D W Boldt; J F De Campo
Journal:  Clin Radiol       Date:  1988-11       Impact factor: 2.350

8.  Pulmonary nodules: detection with thick-section spiral CT versus conventional CT.

Authors:  M Remy-Jardin; J Remy; F Giraud; C H Marquette
Journal:  Radiology       Date:  1993-05       Impact factor: 11.105

9.  High-resolution CT of parenchymal lung disease: precise correlation with histologic findings.

Authors:  L Bessis; P Callard; C Gotheil; A Biaggi; P Grenier
Journal:  Radiographics       Date:  1992-01       Impact factor: 5.333

10.  Reduced need for sedation in patients undergoing helical CT of the chest and abdomen.

Authors:  K S White
Journal:  Pediatr Radiol       Date:  1995
View more
  2 in total

Review 1.  Advances in radiology.

Authors:  T R Goodman; K McHugh
Journal:  Arch Dis Child       Date:  1997-09       Impact factor: 3.791

Review 2.  Invited article: helical/spiral CT scanning: a pediatric radiology perspective.

Authors:  K S White
Journal:  Pediatr Radiol       Date:  1996
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.