Monte Carlo aided dosimetry of the microselectron pulsed and high dose-rate 192Ir sources.

J F Williamson1, Z Li.   

Abstract

Despite the large number of single-stepping source pulsed and high dose-rate (HDR) remote after-loading devices in clinical use, the published literature contain little data characterizing dose-rate distributions around the high-intensity (4 x 10(3)-4 x 10(4) microGy m2h-1) 192Ir sources currently used in these devices. We have used the Monte Carlo method to calculate complete two-dimensional dose-rate distributions about the most widely used high dose-rate source design, as well as the Nucletron pulsed dose-rate (PDR) 192Ir source. A Monte Carlo photon transport code, incorporating the detailed internal geometry of the source, was used to calculate the dose rate per unit air-kerma strength in water medium on the transverse bisecting axis over the 0.15-12 cm distance range. In addition, polar dose profiles were calculated at distances ranging from 0.25 to 5 cm. The PDR and HDR dose-rate distributions are tabulated using the formalism endorsed by the Interstitial Collaborative Working Group and the AAPM Task Group 43, and includes dose-rate constant, radial dose function, anisotropy function, geometry function, and anisotropy factors. The dose-rate constants, lambda, of the MicroSelectron/HDR and PDR sources were found to be 1.115 and 1.128 cGy h-1 per unit air-kerma strength, respectively, in good agreement with previously published data for low dose-rate interstitial 192Ir sources. Oblique filtration by the high-density iridium metal core resulted in deviations from anisotropy as large as 35%-55% near the longitudinal axis of the source. Dose-rate distributions are also presented in Cartesian ("away" and "along") coordinates.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7565372     DOI: 10.1118/1.597483

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Evaluation of Gafchromic EBT2 film for the measurement of anisotropy function for high-dose-rate (192)Ir brachytherapy source with respect to thermoluminescent dosimetry.

Authors:  Satish C Uniyal; Umesh C Naithani; Sunil D Sharma
Journal:  Rep Pract Oncol Radiother       Date:  2010-12-07

2.  Monte Carlo dose calculation of GZP6 (60)Co stepping source based on a matrix shift technique.

Authors:  Mohammad Taghi Bahreyni Toossi; Malihe Abdollahi; Mahdi Ghorbani
Journal:  Rep Pract Oncol Radiother       Date:  2010-12-21

3.  Biphasic and monophasic repair: comparative implications for biologically equivalent dose calculations in pulsed dose rate brachytherapy of cervical carcinoma.

Authors:  W T Millar; J H Hendry; S E Davidson
Journal:  Br J Radiol       Date:  2013-08-09       Impact factor: 3.039

4.  Dosimetric characteristics of the ¹⁹²Ir high-dose-rate afterloading brachytherapy source.

Authors:  Mahdi Sadeghi; Fatemah Taghdiri; Pooneh Saidi
Journal:  Jpn J Radiol       Date:  2011-06-30       Impact factor: 2.374

5.  A Monte Carlo study on dose distribution validation of GZP6 (60)Co stepping source.

Authors:  Mohammad Taghi Bahreyni Toossi; Maliheh Abdollahi; Mahdi Ghorbani
Journal:  Rep Pract Oncol Radiother       Date:  2012-11-21

6.  Comparative dosimetry of GammaMed Plus high-dose rate Ir brachytherapy source.

Authors:  N P Patel; B Majumdar; V Vijayan
Journal:  J Med Phys       Date:  2010-07

7.  Clinical evaluation of radiotherapy for advanced esophageal cancer after metallic stent placement.

Authors:  You-Tao Yu; Guang Yang; Yan Liu; Bao-Zhong Shen
Journal:  World J Gastroenterol       Date:  2004-07-15       Impact factor: 5.742

8.  Dose correction in lung for HDR breast brachytherapy.

Authors:  Eric Slessinger; Eric Pepin; Qingya Zhao; Li Zhao; Indra Das
Journal:  J Contemp Brachytherapy       Date:  2012-06-30

9.  Physics-aspects of dose accuracy in high dose rate (HDR) brachytherapy: source dosimetry, treatment planning, equipment performance and in vivo verification techniques.

Authors:  Antony Palmer; David Bradley; Andrew Nisbet
Journal:  J Contemp Brachytherapy       Date:  2012-06-30

10.  A study on the dose distributions in various materials from an Ir-192 HDR brachytherapy source.

Authors:  Shih-Ming Hsu; Chin-Hui Wu; Jeng-Hung Lee; Ya-Ju Hsieh; Chun-Yen Yu; Yi-Jen Liao; Li-Cheng Kuo; Ji-An Liang; David Y C Huang
Journal:  PLoS One       Date:  2012-09-05       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.