Dosimetric characteristics of a commercial multileaf collimator.

M S Huq1, Y Yu, Z P Chen, N Suntharalingam.   

Abstract

The dosimetric characteristics of a multileaf collimator (MLC) retrofitted to a SL25 linear accelerator have been investigated. Central-axis depth dose, surface dose, penumbra, beam flatness and symmetry, field size factors, beam transmission through leaves and/or diaphragms, and leakage between the leaves were measured. Quantitative measurements of all beam parameters show good agreement with the design specifications of the manufacturer. No changes were observed in flatness, symmetry, penumbra, and penetration for both 6- and 25-MV photon beams when compared to the values for the standard collimator. No significant differences were observed in the penumbra as a function of leaf position. Transmission measurements in areas shielded by either X diaphragms or leaves plus diaphragms are less than 1% of dose within open field. The average leakage between leaves is about 2.5% for 6-MV and 3.5% for 25-MV photon beams. The peak value of the leakage at any point between leaves is less than 5%. The dosimetric features of shaped fields using the MLC are comparable to those of alloy shaped fields with the standard SL25 collimator.

Entities:  

Mesh:

Year:  1995        PMID: 7565356     DOI: 10.1118/1.597461

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  A dosimetric analysis of 6 MV versus 15 MV photon energy plans for intensity modulated radiation therapy (IMRT) of carcinoma of cervix.

Authors:  Atul Tyagi; Sanjay S Supe; Man P Singh
Journal:  Rep Pract Oncol Radiother       Date:  2010-09-22

2.  Physical and dosimetric characteristic of high-definition multileaf collimator (HDMLC) for SRS and IMRT.

Authors:  Dayananda Shamurailatpam Sharma; Prabhakar M Dongre; Vaibav Mhatre; Malhotra Heigrujam
Journal:  J Appl Clin Med Phys       Date:  2011-04-14       Impact factor: 2.102

3.  Dosimetric evaluation of 120-leaf multileaf collimator in a Varian linear accelerator with 6-MV and 18-MV photon beams.

Authors:  R Mohan; K Jayesh; R C Joshi; Maha Al-Idrisi; P Narayanamurthy; Saroj Kumar Das Majumdar
Journal:  J Med Phys       Date:  2008-07

4.  Evaluation of dosimetric effect of leaf position in a radiation field of an 80 leaf multileaf collimator fitted to the LINAC head as tertiary collimator.

Authors:  Than S Kehwar; Anup K Bhardwaj; Shiv K Chakarvarti
Journal:  J Appl Clin Med Phys       Date:  2006-08-24       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.