Theory and validation of access flow measurement by dilution technique during hemodialysis.

N M Krivitski1.   

Abstract

The theory shows that access flow can be measured by the dilution technique by reversal of the blood dialysis lines with the venous outlet facing the access stream: (1.) with one dilution sensor in arterial line and two injections Equation (6); (2.) with two matched dilution sensors on the venous line and on the arterial line and one injection Equation (8); (3.) with blood sampling as for recirculation measurement using BUN or other methods in Equation (12). In all cases, accurate measurement of hemodialysis blood flow is required. The results of this bench validation demonstrate that dialysis blood flows, in the clinical range of 200 to 350 ml/min or more, create good mixing conditions in a vascular access model. Accurate measurements are provided for all clinically significant ranges of access flows, needle positions, and vascular access inner diameters. This simple, non-invasive, and inexpensive technique shows great promise for routine diagnosis of vascular access failure in hemodialysis patients.

Entities:  

Mesh:

Year:  1995        PMID: 7564085     DOI: 10.1038/ki.1995.290

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  22 in total

1.  Hemodialysis vascular assessment by an ultrasound dilution method (transonic) in patients older than 65 years.

Authors:  G Barril; E Besada; A Cirugeda; A F Perpen; R Selgas
Journal:  Int Urol Nephrol       Date:  2001       Impact factor: 2.370

2.  Effectiveness of beraprost sodium in maintaining vascular access patency in patients on hemodialysis.

Authors:  Miyeon Kim; Ji Ung Kim; So Mi Kim; HyunWoo Kim
Journal:  Int Urol Nephrol       Date:  2017-04-13       Impact factor: 2.370

Review 3.  A meta-analysis of randomized clinical trials assessing hemodialysis access thrombosis based on access flow monitoring: where do we stand?

Authors:  Timothy Muchayi; Loay Salman; Leonardo J Tamariz; Arif Asif; Abid Rizvi; Oliver Lenz; Roberto I Vazquez-Padron; Marwan Tabbara; Gabriel Contreras
Journal:  Semin Dial       Date:  2015-01-28       Impact factor: 3.455

4.  Flexible, Skin Coupled Microphone Array for Point of Care Vascular Access Monitoring.

Authors:  Binit Panda; Soumyajit Mandal; Steve J A Majerus
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2019-10-18       Impact factor: 3.833

Review 5.  Monitoring and Surveillance of Hemodialysis Access.

Authors:  Nischal Koirala; Evamaria Anvari; Gordon McLennan
Journal:  Semin Intervent Radiol       Date:  2016-03       Impact factor: 1.513

6.  The measurement of hemodialysis access blood flow by a conductivity step method.

Authors:  Robert M Lindsay; Shih-Han S Huang; Jan Sternby; Thomas Hertz
Journal:  Clin J Am Soc Nephrol       Date:  2010-07-08       Impact factor: 8.237

7.  Ultrasound dilution and thermodilution versus color Doppler ultrasound for arteriovenous fistula assessment in children on hemodialysis.

Authors:  Vasiliki Karava; Theresa Kwon; Gilbert Franco; Deschenes Georges; Marie-Alice Macher; Julien Hogan
Journal:  Pediatr Nephrol       Date:  2019-07-19       Impact factor: 3.714

8.  Early vascular access blood flow as a predictor of long-term vascular access patency in incident hemodialysis patients.

Authors:  Hyung Soo Kim; Jin-Woong Park; Jae Hyun Chang; Jaeseok Yang; Hyun Hee Lee; Wookyung Chung; Yeon Ho Park; Sejoong Kim
Journal:  J Korean Med Sci       Date:  2010-04-22       Impact factor: 2.153

9.  Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients.

Authors:  Nikolai M Krivitski; Victor V Kislukhin; Naveen V Thuramalla
Journal:  Pediatr Crit Care Med       Date:  2008-07       Impact factor: 3.624

10.  Accuracy of volumetric flow rate measurements: an in vitro study using modern ultrasound scanners.

Authors:  Kenneth Hoyt; Felix A Hester; Randall L Bell; Mark E Lockhart; Michelle L Robbin
Journal:  J Ultrasound Med       Date:  2009-11       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.