Literature DB >> 27013773

Monitoring and Surveillance of Hemodialysis Access.

Nischal Koirala1, Evamaria Anvari2, Gordon McLennan3.   

Abstract

Access surveillance using invasive or noninvasive methods with an objective to improve access patency and decrease hospital admissions for access dysfunction in dialysis population has been promoted, but its success to predict incipient thrombosis and subsequent access failure is a controversial topic. Some studies have shown improvement in access outcomes, while others have failed to demonstrate an ideal method to diagnose access problems. Furthermore, the use of endovascular interventions such as percutaneous transluminal angioplasty to timely correct access problem might itself be a promoter of neointimal hyperplasia and restenosis during balloon angioplasty. There are significant costs and efforts associated with routine dialysis surveillance; therefore, it is necessary to understand whether such programs will help improve access-related problems and guarantee adequate dialysis care. It is generally agreed upon that despite the lack of guaranteed success of surveillance, such strategies have helped improve dialysis management, resulted in decreased costs and hospitalizations, and represented clinically relevant indications of failure prior to planning any radiological or surgical intervention. In this study, the authors review monitoring and surveillance measures in place, and their associated merits and limitations to detect stenosis and prevent incidences of vascular access thrombosis.

Entities:  

Keywords:  arteriovenous fistula; arteriovenous graft; interventional radiology; monitoring; surveillance; vascular access

Year:  2016        PMID: 27013773      PMCID: PMC4806702          DOI: 10.1055/s-0036-1572548

Source DB:  PubMed          Journal:  Semin Intervent Radiol        ISSN: 0739-9529            Impact factor:   1.513


  26 in total

1.  Determination of access blood flow from ionic dialysance: theory and validation.

Authors:  L Mercadal; A Hamani; B Béné; T Petitclerc
Journal:  Kidney Int       Date:  1999-10       Impact factor: 10.612

2.  Analysis of variable flow Doppler hemodialysis access flow measurements and comparison with ultrasound dilution.

Authors:  W F Weitzel; J M Rubin; S F Leavey; R D Swartz; R K Dhingra; J M Messana
Journal:  Am J Kidney Dis       Date:  2001-11       Impact factor: 8.860

3.  Noninvasive transcutaneous determination of access blood flow rate.

Authors:  R R Steuer; D R Miller; S Zhang; D A Bell; J K Leypoldt
Journal:  Kidney Int       Date:  2001-07       Impact factor: 10.612

4.  Measurement of access flow during hemodialysis using the constant infusion approach.

Authors:  D Schneditz; Z Fan; A Kaufman; N W Levin
Journal:  ASAIO J       Date:  1998 Jan-Feb       Impact factor: 2.872

5.  Accuracy of dilution techniques for access flow measurement during hemodialysis.

Authors:  N M Krivitski; D MacGibbon; R D Gleed; A Dobson
Journal:  Am J Kidney Dis       Date:  1998-03       Impact factor: 8.860

6.  The relationship of recirculation to access blood flow.

Authors:  A Besarab; R Sherman
Journal:  Am J Kidney Dis       Date:  1997-02       Impact factor: 8.860

7.  A comparison of methods for the measurement of hemodialysis access recirculation and access blood flow rate.

Authors:  R M Lindsay; E Bradfield; C Rothera; C Kianfar; P Malek; P G Blake
Journal:  ASAIO J       Date:  1998 Jan-Feb       Impact factor: 2.872

8.  US Renal Data System 2014 Annual Data Report: Epidemiology of Kidney Disease in the United States.

Authors:  Rajiv Saran; Yi Li; Bruce Robinson; John Ayanian; Rajesh Balkrishnan; Jennifer Bragg-Gresham; Joline T L Chen; Elizabeth Cope; Debbie Gipson; Kevin He; William Herman; Michael Heung; Richard A Hirth; Steven S Jacobsen; Kamyar Kalantar-Zadeh; Csaba P Kovesdy; Alan B Leichtman; Yee Lu; Miklos Z Molnar; Hal Morgenstern; Brahmajee Nallamothu; Ann M O'Hare; Ronald Pisoni; Brett Plattner; Friedrich K Port; Panduranga Rao; Connie M Rhee; Douglas E Schaubel; David T Selewski; Vahakn Shahinian; John J Sim; Peter Song; Elani Streja; Manjula Kurella Tamura; Francesca Tentori; Paul W Eggers; Lawrence Y C Agodoa; Kevin C Abbott
Journal:  Am J Kidney Dis       Date:  2015-07       Impact factor: 8.860

9.  Clinical measurement of blood flow in hemodialysis access fistulae and grafts by ultrasound dilution.

Authors:  T A Depner; N M Krivitski
Journal:  ASAIO J       Date:  1995 Jul-Sep       Impact factor: 2.872

10.  Accuracy of physical examination in the detection of arteriovenous graft stenosis.

Authors:  Carlos Leon; Luis Carlos Orozco-Vargas; Gururaj Krishnamurthy; Kenneth L Choi; Carlos Mercado; Donna Merrill; Ian Thomas; Loay Salman; Shukhrat Artikov; Jacques J Bourgoignie; Arif Asif
Journal:  Semin Dial       Date:  2008 Jan-Feb       Impact factor: 3.455

View more
  3 in total

Review 1.  Hemodialysis access thrombosis.

Authors:  Keith Bertram Quencer; Rahmi Oklu
Journal:  Cardiovasc Diagn Ther       Date:  2017-12

2.  Catheter Port Reversal in Citrate Continuous Veno-Venous Hemofiltration.

Authors:  Willem Boer; Mathias Van Tornout; Margot Vander Laenen; Kim Engelen; Ingrid Meex; Philippe Jorens
Journal:  Kidney Int Rep       Date:  2021-08-13

Review 3.  Cardiovascular implantable electronic devices and native arteriovenous fistula in hemodialysis patients: novel perspectives.

Authors:  Leonardo Spatola; Rodolfo Fernando Rivera; Giacomo Mugnai
Journal:  Int Urol Nephrol       Date:  2021-03-16       Impact factor: 2.370

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.