Literature DB >> 7558360

Corrosion evaluation of recasting non-precious dental alloys.

E Khamis1, M Seddik.   

Abstract

The effect of recasting, up to four times, non precious Ni-Cr and Co-Cr commercial dental alloys on their corrosion behaviour in saliva and saline media was carried out. A potentiokinetic technique was utilised to analyse the electrochemical characteristics of the anodic polarisation curves of these alloys. A considerable anodic polarisation range (about 2.0 V vs SCE) was used to investigate the possibility of developing a passive regime at such high potential range. The most important feature noted was a rapid rise in current density above a certain critical potential called pitting potential, Ep. The experimental data show that the open circuit potential, Eoc does not enable differentiation between the corrosion resistance of the four alloys used in this study. However, Ep and the rupture potential Er does distinguish between them. Increasing the number of the successive recastings of Wirolloy leads to enhancing the pitting potential, thus, the corrosion resistance of Wirolloy (Ni-Cr) improves after remelting and recasting. It has been found that Wirolloy corrodes 26 times faster than Wironit alloy under the same solution. The alloys containing cobalt and molybdenum show higher corrosion resistance than those containing nickel. Additionally, their corrosion resistance was not affected by successive melting and recasting. In chloride solutions Ni-Cr alloys show a high susceptibility to pitting corrosion, while Co-Cr alloys show a noble behaviour. The corrosion resistance of the four non precious alloys were in the following order: Biocast > Wironit > Cobond > Wirolloy.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7558360

Source DB:  PubMed          Journal:  Int Dent J        ISSN: 0020-6539            Impact factor:   2.512


  6 in total

1.  Microstructure analysis of dental castings used in fixed dental prostheses--a simple method for quality control.

Authors:  Christian Mehl; Björn Lang; Heinrich Kappert; Matthias Kern
Journal:  Clin Oral Investig       Date:  2010-03-16       Impact factor: 3.573

2.  Customised attachments retained cheek plumper prosthesis: a case report.

Authors:  Nandita N Keni; Meena A Aras; Vidya Chitre
Journal:  J Indian Prosthodont Soc       Date:  2012-06-08

3.  Tooth Supported Overdenture Retained with Custom Attachments: A Case Report.

Authors:  Siddharth Bansal; Meena A Aras; Vidya Chitre
Journal:  J Indian Prosthodont Soc       Date:  2013-12-12

4.  Comparative Evaluation of Marginal and Internal Gap of Co-Cr Copings Fabricated from Conventional Wax Pattern, 3D Printed Resin Pattern and DMLS Tech: An In Vitro Study.

Authors:  Eswaran Bhaskaran; N S Azhagarasan; Saket Miglani; T Ilango; G Phani Krishna; B Gajapathi
Journal:  J Indian Prosthodont Soc       Date:  2013-05-03

5.  Effect of Recasting on Physical Properties of Base Metal Alloys: An In Vitro Study.

Authors:  Jittin James; Jose Julian; J Rahul; Gibi Babu Philip; Jinsa P Devassy; P B Reba
Journal:  J Int Soc Prev Community Dent       Date:  2018-10-08

6.  Corrosion Behavior of a Nickel-Base Dental Casting Alloy in Artificial Saliva Studied by Weight Loss and Polarization Techniques.

Authors:  Elnaz Moslehifard; Mahsa Moslehifard; Sanaz Ghasemzadeh; Farzad Nasirpouri
Journal:  Front Dent       Date:  2019-01-20
  6 in total