Literature DB >> 7557583

High resolution magnetic resonance imaging of the anal sphincter using an internal coil.

N M deSouza1, W A Kmiot, R Puni, A S Hall, M Burl, C I Bartram, G M Bydder.   

Abstract

An internal receiver coil was used to obtain high resolution transverse and oblique coronal magnetic resonance images of the anal sphincter in five normal volunteers and five patients. The internal sphincter had a high signal intensity on T1 weighted, T2 weighted, and STIR sequences whereas the conjoined longitudinal muscle and external sphincter had a low signal intensity. The internal sphincter (but not the external sphincter) showed contrast enhancement after administration of intravenous gadopentetate dimeglumine. The oblique coronal plane was particularly useful for showing the thickness and the relations of the external sphincter. Sphincteric abscesses as well as muscle defects, hypertrophy, and atrophy were clearly shown. The coil was well tolerated by most subjects. It has considerable potential for improving the diagnosis of anorectal disease.

Entities:  

Mesh:

Year:  1995        PMID: 7557583      PMCID: PMC1382733          DOI: 10.1136/gut.37.2.284

Source DB:  PubMed          Journal:  Gut        ISSN: 0017-5749            Impact factor:   23.059


  3 in total

1.  Anal endosonography and correlation with in vitro and in vivo anatomy.

Authors:  A H Sultan; R J Nicholls; M A Kamm; C N Hudson; J Beynon; C I Bartram
Journal:  Br J Surg       Date:  1993-04       Impact factor: 6.939

2.  Anatomy of the anal sphincters. Comparison of anal endosonography to magnetic resonance imaging.

Authors:  A Schäfer; P Enck; G Fürst; T Kahn; T Frieling; H J Lübke
Journal:  Dis Colon Rectum       Date:  1994-08       Impact factor: 4.585

3.  Endosonography of the anal sphincters: normal anatomy and comparison with manometry.

Authors:  A H Sultan; M A Kamm; C N Hudson; J R Nicholls; C I Bartram
Journal:  Clin Radiol       Date:  1994-06       Impact factor: 2.350

  3 in total
  3 in total

Review 1.  Idiopathic fistula-in-ano.

Authors:  Sherief Shawki; Steven D Wexner
Journal:  World J Gastroenterol       Date:  2011-07-28       Impact factor: 5.742

2.  Diagnostic precision of endoanal MRI in the detection of anal sphincter pathology: a meta-analysis.

Authors:  Emile Tan; Ann Anstee; Dow-Mu Koh; Wadyslaw Gedroyc; Paris P Tekkis
Journal:  Int J Colorectal Dis       Date:  2008-03-11       Impact factor: 2.571

3.  New coil concept for endoluminal MR imaging: initial results in staging of gastric carcinoma in correlation with histopathology.

Authors:  Tobias Heye; Christian Kuntz; Marcus Düx; Jens Encke; Moritz Palmowski; Frank Autschbach; Frank Volke; Guenter Werner Kauffmann; Lars Grenacher
Journal:  Eur Radiol       Date:  2006-05-30       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.