Literature DB >> 7554651

Preclinical testing of total hip stems. The effects of coating placement.

R Huiskes1, B van Rietbergen.   

Abstract

The long-term fixation endurance of noncemented hip stems in total hip arthroplasty is subject to incompatible design goals. To reduce stress shielding and periprosthetic bone loss, proximal fixation and load transfer are indicated. However, to prevent interface motion and promote interface-bonding security, fixation preferably should be maximized over the entire stem surface. In this study, the authors questioned whether hydroxyapatite coatings could be applied in patterns that reduce bone resorption, while maintaining safe interface stress levels. For that purpose, strain-adaptive bone-remodeling theory was applied in 3-dimensional finite element models, to simulate the long-term postoperative bone resorption process. During the process, the adaptation of interface stresses was monitored, and its effects on interface failure probability evaluated. This analysis was done for a fully coated stem, a 1/3 proximally coated stem, a smooth uncoated, press-fitted stem, and a stem with 5 proximal patches of circumferential stripes. The uncoated stem reduced bone loss dramatically, but promoted interface motions and distal pedestal formation. In all cases, the gradual bone-remodeling process increased the interface security of the coated stems. Bone loss and interface failure probability were not very different for the fully and 1/3-coated stems. Stripe coating reduced bone resorption considerably, while increasing long-term interface failure probability only slightly. The investigators concluded that the initial stability and the ingrowth potential of such a stem design are likely to be inadequate.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7554651

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  10 in total

1.  Numeric simulation of bone remodelling patterns after implantation of a cementless straight stem.

Authors:  Matthias Lerch; Henning Windhagen; Christina M Stukenborg-Colsman; Agnes Kurtz; Bernd A Behrens; Amer Almohallami; Anas Bouguecha
Journal:  Int Orthop       Date:  2013-08-31       Impact factor: 3.075

2.  [Applications of numerical simulation in musculoskeletal research and its impact on orthopedic surgery].

Authors:  D Kluess; C Hurschler; C Voigt; A Hölzer; M Stoffel
Journal:  Orthopade       Date:  2013-04       Impact factor: 1.087

3.  Analyzing bone remodeling patterns after total hip arthroplasty using quantitative computed tomography and patient-specific 3D computational models.

Authors:  Shanika Arachchi; Rocco P Pitto; Iain A Anderson; Vickie B Shim
Journal:  Quant Imaging Med Surg       Date:  2015-08

4.  A comparative finite-element analysis of bone failure and load transfer of osseointegrated prostheses fixations.

Authors:  P K Tomaszewski; N Verdonschot; S K Bulstra; G J Verkerke
Journal:  Ann Biomed Eng       Date:  2010-03-23       Impact factor: 3.934

5.  Late remodeling around a proximally HA-coated tapered titanium femoral component.

Authors:  William N Capello; James A D'Antonio; Rudolph G Geesink; Judy R Feinberg; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2008-10-11       Impact factor: 4.176

6.  Numerical simulation of strain-adaptive bone remodelling in the ankle joint.

Authors:  Anas Bouguecha; Nelly Weigel; Bernd-Arno Behrens; Christina Stukenborg-Colsman; Hazibullah Waizy
Journal:  Biomed Eng Online       Date:  2011-07-05       Impact factor: 2.819

7.  The geometry of the bone structure associated with total hip arthroplasty.

Authors:  Zhang Yang; Wang Jian; Zhi-han Li; Xiao Jun; Zhao Liang; Yan Ge; Zhan-jun Shi
Journal:  PLoS One       Date:  2014-03-07       Impact factor: 3.240

8.  Cementless hydroxyapatite coated hip prostheses.

Authors:  Antonio Herrera; Jesús Mateo; Jorge Gil-Albarova; Antonio Lobo-Escolar; Elena Ibarz; Sergio Gabarre; Yolanda Más; Luis Gracia
Journal:  Biomed Res Int       Date:  2015-02-23       Impact factor: 3.411

9.  Numerical investigations on the strain-adaptive bone remodelling in the periprosthetic femur: influence of the boundary conditions.

Authors:  Bernd-Arno Behrens; Ingo Nolte; Patrick Wefstaedt; Christina Stukenborg-Colsman; Anas Bouguecha
Journal:  Biomed Eng Online       Date:  2009-04-16       Impact factor: 2.819

10.  Generic rules of mechano-regulation combined with subject specific loading conditions can explain bone adaptation after THA.

Authors:  Tomasz D Szwedowski; William R Taylor; Markus O Heller; Carsten Perka; Michael Müller; Georg N Duda
Journal:  PLoS One       Date:  2012-05-02       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.