BACKGROUND: The hydroxyapatite (HA) intraorbital implant is a relatively new implant made from the porous skeleton of a coral species which allows fibrovascular ingrowth and therefore tissue integration. After fibrovascular ingrowth, a hole can be drilled in the implant and a motility peg inserted to increase movements of the prosthesis by coupling the implant to the prosthesis.
METHOD: The records of the first 100 cases of HA intraorbital implants inserted by the one surgeon were analysed for complications, pain and nausea postoperatively, length of hospital stay, and further surgical procedures required. A series of acrylic implants inserted by the same surgeon was used for comparison.
RESULTS: Twenty-five primary and 75 secondary HA implants were performed in patients ranging from six to 74 years of age. All were covered in donor sclera. Follow-up was three to 34 months (mean 16.9, median 17.0). Complications occurred in 15 patients and included too large an implant (seven cases) requiring surgical reduction, scleral exposure in three (repair required in one), an early small exposure of the coral in one case, late thinning of the conjunctiva and later exposure of the implant in one, and shallowing of the inferior fornix requiring mucous membrane grafting in three. No implants migrated, extruded or became infected. Of 80 patients beyond six months follow-up, 28 (35%) had insertion of motility pegs, and six (7.5%) of these suffered minor complications related to the peg. Compared to patients having acrylic implants, the postoperative analgesic requirements and length of hospital stay were significantly greater for the HA patients.
CONCLUSIONS: Hydroxyapatite intraorbital implants represent a significant advance over other implants and offer a more stable, safe alternative. They also offer the possibility of improved prosthesis motility. The additional cost of the implant, prolonged hospital stay and postoperative pain, should be considered in recommending such implants to patients either as primary or secondary implants.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7546686     DOI: 10.1111/j.1442-9071.1995.tb00139.x

Source DB:  PubMed          Journal:  Aust N Z J Ophthalmol        ISSN: 0814-9763


  5 in total

1.  Correlation of histological findings with gadolinium enhanced MRI scans during healing of a PHEMA orbital implant in rabbits.

Authors:  C R Hicks; I T Morris; S Vijayasekaran; M J Fallon; J McAllister; A B Clayton; T V Chirila; G J Crawford; I J Constable
Journal:  Br J Ophthalmol       Date:  1999-05       Impact factor: 4.638

2.  Autogenous temporalis fascia patch graft for porous polyethylene (Medpor) sphere orbital implant exposure.

Authors:  M S Sagoo; J M Olver
Journal:  Br J Ophthalmol       Date:  2004-07       Impact factor: 4.638

3.  Amniotic membrane transplantation for porous sphere orbital implant exposure.

Authors:  Yan-hong Chen; Hong-guang Cui
Journal:  J Zhejiang Univ Sci B       Date:  2007-09       Impact factor: 3.066

4.  High density porous polyethylene material (Medpor) as an unwrapped orbital implant.

Authors:  Yan-hong Chen; Hong-guang Cui
Journal:  J Zhejiang Univ Sci B       Date:  2006-08       Impact factor: 3.066

5.  Long-term surgical outcomes of porous polyethylene orbital implants: a review of 314 cases.

Authors:  Su-Kyung Jung; Won-Kyung Cho; Ji-Sun Paik; Suk-Woo Yang
Journal:  Br J Ophthalmol       Date:  2011-11-17       Impact factor: 4.638

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.