Literature DB >> 7528123

Effect of fixation on quantification of the expression of leucocyte function-associated surface antigens.

D A McCarthy1, M G Macey, M R Cahill, A C Newland.   

Abstract

The surface expression of adhesion molecules and other function-associated antigens on peripheral blood leucocytes may be measured by flow cytometry. However, quantification of these antigens is difficult, because their expression can be rapidly and artefactually modulated if the cells are activated in vitro. Consequently, it is common, when analyzing these antigens either: (1) to label leucocytes in whole blood at 4 degrees C, to lyse erythrocytes and then fix the leucocytes, or (2) to fix the leucocytes in whole blood, to lyse the erythrocytes, and then label the leucocytes. We have compared the mean fluorescence intensity (MFI) values for CD11b, CD18, and L-selectin (Leu-8 and TQ1 epitopes) on human peripheral blood leucocytes, using these two approaches. In addition, we have simultaneously evaluated how anticoagulants (acid citrate, K3EDTA, and heparin) and the presence or absence of divalent metal ions (Ca2+ and Mg2+) affect the expression levels of these antigens. The results for all four epitopes varied markedly depending on the preparation procedure used but were less affected by the choice of anticoagulant and whether divalent cations were or were not present in the media used for cell preparation and labelling. Comparison of the results obtained using these procedures, which involve fixation with formaldehyde, with those obtained by a recently developed procedure in which unfixed leucocytes were labelled with the vital nuclear dye LDS-751 and antibodies together, then analysed in unlysed whole blood at 4 degrees C, showed that formaldehyde-based preparation techniques underestimated the expression (MFI) of CD18, Leu-8, and TQ1. It is recommended that, whenever practicable, measurements are made on unfixed cells stained using the newer procedure.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 7528123     DOI: 10.1002/cyto.990170106

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  9 in total

1.  Primed PMNs in healthy mouse and human circulation are first responders during acute inflammation.

Authors:  Noah Fine; Oriyah Barzilay; Chunxiang Sun; Nimali Wellappuli; Farzeen Tanwir; Jeffrey W Chadwick; Morvarid Oveisi; Nikola Tasevski; David Prescott; Martin Gargan; Dana J Philpott; Yigal Dror; Michael Glogauer
Journal:  Blood Adv       Date:  2019-05-28

2.  Shear-induced capping of L-selectin on the neutrophil surface during centrifugation.

Authors:  Dooyoung Lee; Michael R King
Journal:  J Immunol Methods       Date:  2007-09-12       Impact factor: 2.303

3.  What you need to know when you go with the flow: pitfalls in the use of flow cytometry.

Authors:  M Pallis; R A Robins
Journal:  Ann Rheum Dis       Date:  1995-10       Impact factor: 19.103

4.  Comparison of sample fixation and the use of LDS-751 or anti-CD45 for leukocyte identification in mouse whole blood for flow cytometry.

Authors:  Melissa L Maes; Lisa B Davidson; Paul F McDonagh; Leslie S Ritter
Journal:  J Immunol Methods       Date:  2006-12-08       Impact factor: 2.303

5.  Determining beta2-integrin and intercellular adhesion molecule 1 binding kinetics in tumor cell adhesion to leukocytes and endothelial cells by a gas-driven micropipette assay.

Authors:  Changliang Fu; Chunfang Tong; Manliu Wang; Yuxin Gao; Yan Zhang; Shouqin Lü; Shile Liang; Cheng Dong; Mian Long
Journal:  J Biol Chem       Date:  2011-08-12       Impact factor: 5.157

6.  Differential expression of T cell antigens in normal peripheral blood lymphocytes: a quantitative analysis by flow cytometry.

Authors:  L Ginaldi; N Farahat; E Matutes; M De Martinis; R Morilla; D Catovsky
Journal:  J Clin Pathol       Date:  1996-07       Impact factor: 3.411

7.  Development of a Comprehensive Antibody Staining Database Using a Standardized Analytics Pipeline.

Authors:  El-Ad David Amir; Brian Lee; Paul Badoual; Martin Gordon; Xinzheng V Guo; Miriam Merad; Adeeb H Rahman
Journal:  Front Immunol       Date:  2019-06-11       Impact factor: 7.561

8.  Multiplex cytokine profiling with highly pathogenic material: use of formalin solution in luminex analysis.

Authors:  Stuart D Dowall; Victoria A Graham; Thomas R W Tipton; Roger Hewson
Journal:  J Immunol Methods       Date:  2009-06-26       Impact factor: 2.303

9.  Investigation of the response of tear-film neutrophils to interleukin 8 and their sensitivity to centrifugation, fixation, and incubation.

Authors:  Yutong Jin; Lyndon Jones; Maud Gorbet
Journal:  Sci Rep       Date:  2020-11-12       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.