Literature DB >> 17187818

Comparison of sample fixation and the use of LDS-751 or anti-CD45 for leukocyte identification in mouse whole blood for flow cytometry.

Melissa L Maes1, Lisa B Davidson, Paul F McDonagh, Leslie S Ritter.   

Abstract

Flow cytometry methods used to measure leukocyte function often entail sample preparation procedures that cause artifactual cell activation. To avoid leukocyte activation by isolation techniques, some preparation methods use fluorescent markers to discriminate leukocytes from erythrocytes in whole blood. One of these markers, laser dye styryl-751(LDS-751), has been used to distinguish leukocytes by staining nucleic acid, but has been found to stain other blood cells and dead cells indiscriminately. Thus, LDS-751 may not be an appropriate reagent for leukocyte identification in whole blood. Fixing samples with formaldehydes increases cell permeability and causes surface protein cross-linking that may alter staining of both intra- and extracellular markers. The degree of this sample alteration by formaldehyde fixation, however, remains in question. In addition, little is known about flow cytometry and sample preparation methods in mouse whole blood. The purpose of this study was to determine if labeling leukocytes with a monoclonal antibody specific to leukocyte common antigen (CD45) was superior to labeling with LDS-751 and to determine the effect of sample fixation on a mouse whole blood preparation for flow cytometry. Samples were incubated with CD16/CD32 Fc receptor blocker, and either 10 microg/ml LDS-751 or phosphate buffered saline (PBS). The samples were then fixed with paraformaldehyde or diluted with PBS followed by incubation with 5 microg/ml PerCP-conjugated anti-CD45, 5 microg/ml FITC-conjugated anti-CD11b, or 80 microM dichlorofluorescein diacetate. We found that samples labeled with LDS-751 demonstrated decreased fluorescence intensity for granulocyte CD11b expression and ROS production compared to samples labeled with anti-CD45. In addition, sample fixation decreased mean fluorescence intensity in samples labeled with either LDS-751 or anti-CD45. We conclude that labeling leukocytes with monoclonal antibody CD45 in a mouse whole blood preparation is preferable, as it provides improved measurement of leukocyte indices compared to LDS-751. Also, while sample fixation prior to antibody staining caused a decrease in overall fluorescence; it can be used to successfully identify extra-cellular markers.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17187818      PMCID: PMC1896319          DOI: 10.1016/j.jim.2006.10.016

Source DB:  PubMed          Journal:  J Immunol Methods        ISSN: 0022-1759            Impact factor:   2.303


  26 in total

Review 1.  Introduction to flow cytometry.

Authors:  G E Marti; M Stetler-Stevenson; J J Bleesing; T A Fleisher
Journal:  Semin Hematol       Date:  2001-04       Impact factor: 3.851

2.  Evaluation of circulating platelet-leukocyte conjugates: a sensitive flow cytometric assay well suited for clinical studies.

Authors:  I A Hagberg; T Lyberg
Journal:  Platelets       Date:  2000-05       Impact factor: 3.862

Review 3.  CD45: a critical regulator of signaling thresholds in immune cells.

Authors:  Michelle L Hermiston; Zheng Xu; Arthur Weiss
Journal:  Annu Rev Immunol       Date:  2001-12-19       Impact factor: 28.527

4.  Preparative procedures of cooling and re-warming increase leukocyte integrin expression and function on neutrophils.

Authors:  K D Forsyth; R J Levinsky
Journal:  J Immunol Methods       Date:  1990-04-17       Impact factor: 2.303

5.  A rapid sample preparation technique for flow cytometric analysis of immunofluorescence allowing absolute enumeration of cell subpopulations.

Authors:  L W Terstappen; H Meiners; M R Loken
Journal:  J Immunol Methods       Date:  1989-09-29       Impact factor: 2.303

6.  Leukocytes can enhance platelet-mediated aggregation and thromboxane release via interaction of P-selectin glycoprotein ligand 1 with P-selectin.

Authors:  N Faraday; R B Scharpf; J M Dodd-o; E A Martinez; B A Rosenfeld; T Dorman
Journal:  Anesthesiology       Date:  2001-01       Impact factor: 7.892

7.  Flow cytometric method for enumeration and classification of reactive immature granulocyte populations.

Authors:  H Fujimoto; T Sakata; Y Hamaguchi; S Shiga; K Tohyama; S Ichiyama; F S Wang; B Houwen
Journal:  Cytometry       Date:  2000-12-15

8.  Assessment of neutrophil activation in whole blood by flow cytometry.

Authors:  A Alvarez-Larrán; T Toll; S Rives; J Estella
Journal:  Clin Lab Haematol       Date:  2005-02

9.  CD45-associated protein inhibits CD45 dimerization and up-regulates its protein tyrosine phosphatase activity.

Authors:  Akiko Takeda; Akio Matsuda; Rachelle M J Paul; Nabeel R Yaseen
Journal:  Blood       Date:  2004-01-08       Impact factor: 22.113

10.  Flow cytometric studies of oxidative product formation by neutrophils: a graded response to membrane stimulation.

Authors:  D A Bass; J W Parce; L R Dechatelet; P Szejda; M C Seeds; M Thomas
Journal:  J Immunol       Date:  1983-04       Impact factor: 5.422

View more
  6 in total

1.  Systemic neutrophil activation in a mouse model of ischemic stroke and reperfusion.

Authors:  Helena Morrison; Dana McKee; Leslie Ritter
Journal:  Biol Res Nurs       Date:  2010-11-01       Impact factor: 2.522

Review 2.  Immunological methods for nursing research: from cells to systems.

Authors:  Helena W Morrison; Charles A Downs
Journal:  Biol Res Nurs       Date:  2011-03-30       Impact factor: 2.522

3.  Validation of a flow cytometry based binding assay for evaluation of monoclonal antibody recognizing EGF receptor.

Authors:  Mercedes Cedeño-Arias; Javier Sánchez-Ramírez; Rancés Blanco-Santana; Enrique Rengifo-Calzado
Journal:  Sci Pharm       Date:  2011-07-03

4.  Ex vivo modelling of the formation of inflammatory platelet-leucocyte aggregates and their adhesion on endothelial cells, an early event in sepsis.

Authors:  Azzah Alharbi; Jonathan P Thompson; Nicholas P Brindle; Cordula M Stover
Journal:  Clin Exp Med       Date:  2018-09-06       Impact factor: 3.984

5.  Multiplex cytokine profiling with highly pathogenic material: use of formalin solution in luminex analysis.

Authors:  Stuart D Dowall; Victoria A Graham; Thomas R W Tipton; Roger Hewson
Journal:  J Immunol Methods       Date:  2009-06-26       Impact factor: 2.303

6.  A flow cytometry technique to study intracellular signals NF-kappaB and STAT3 in peripheral blood mononuclear cells.

Authors:  Sandrine Lafarge; Hind Hamzeh-Cognasse; Patricia Chavarin; Christian Genin; Olivier Garraud; Fabrice Cognasse
Journal:  BMC Mol Biol       Date:  2007-07-31       Impact factor: 2.946

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.