Literature DB >> 7513882

In vivo ventricular lesion growth in radiofrequency catheter ablation.

T A Simmers1, F H Wittkampf, R N Hauer, E O Robles de Medina.   

Abstract

While radiofrequency catheter ablation has proved highly effective in the treatment of various supraventricular tachyarrhythmias, results in the treatment of ventricular tachycardia invite improvement. Knowledge of lesion growth in vivo might improve understanding of this discrepancy. So far only information from in vitro and in vivo studies using a small 2 mm tip electrode is available. Growth of ventricular radiofrequency lesions created with a 4 mm ablation electrode was studied in 11 closed-chest dogs. Endocardial ablations were performed at 31 left and 15 right ventricular sites at a power setting of 25 Watts and 5, 10, 20, 30 or 60 seconds pulse duration. Macroscopic and histopathologic lesion examination were performed after one week survival. Mean lesion volume increased from 52 mm3 after 5 seconds pulse duration to a maximum 388 mm3 and approximately 7 mm depth after 30 seconds. Lesions were prolate spheroid in form, with a sparing of subendocardial myocardium and maximum lesion diameter at some millimeters depth. Results indicate that catheter positioning at no more than 7 mm from the target is required for successful ablation. Due to lesion geometry, subendocardial targets demand even more exact catheter positioning, while subepicardial substrates may not be ammenable to ablation if ventricular wall thickness exceeds 7 mm at the ablation site. Repeated pulses at adjacent sites may be required for ablation of extended arrhythmogenic areas. Volume at 5 seconds was only approximately 15% of mature lesions. Therefore, the use of a short 'test pulse' after careful mapping may be useful to pinpoint the most appropriate site for ablation in discrete pathways.

Entities:  

Mesh:

Year:  1994        PMID: 7513882     DOI: 10.1111/j.1540-8159.1994.tb01421.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  11 in total

1.  Assessment of spatial resolution of pace mapping when using body surface potentials.

Authors:  R Hren; B B Punske; G Stroink
Journal:  Med Biol Eng Comput       Date:  1999-07       Impact factor: 2.602

2.  Direct thermography-a new in vitro method to characterize temperature kinetics of ablation catheters.

Authors:  M Fiek; F Gindele; C von Bary; D Muessig; A Lucic; E Hoffmann; C Reithmann; G Steinbeck
Journal:  J Interv Card Electrophysiol       Date:  2013-07-14       Impact factor: 1.900

3.  Recurrence of accessory pathway conduction after successful radiofrequency ablation: histological findings.

Authors:  V P Vassilikos; S Y Ho; C Y Wong; A W Nathan
Journal:  J Interv Card Electrophysiol       Date:  1997-12       Impact factor: 1.900

4.  Intracardiac echocardiographic evaluation of ventricular mural swelling from radiofrequency ablation in chronic myocardial infarction: irrigated-tip versus standard catheter.

Authors:  J F Ren; D J Callans; J J Michele; S M Dillon; F E Marchlinski
Journal:  J Interv Card Electrophysiol       Date:  2001-03       Impact factor: 1.900

5.  Conversion of left ventricular endocardial positions from patient-independent co-ordinates into biplane fluoroscopic projections.

Authors:  M Potse; R Hoekema; A C Linnenbank; A SippensGroenewegen; J Strackee; Bakker J M T de; C A Grimbergen
Journal:  Med Biol Eng Comput       Date:  2002-01       Impact factor: 2.602

6.  Cooled-tip ablation results in increased radiofrequency power delivery and lesion size in the canine heart: importance of catheter-tip temperature monitoring for prevention of popping and impedance rise.

Authors:  Ichiro Watanabe; Riko Masaki; Nuo Min; Naohiro Oshikawa; Kimie Okubo; Hidezou Sugimura; Toshiaki Kojima; Satoshi Saito; Yukio Ozawa; Katsuo Kanmatsuse
Journal:  J Interv Card Electrophysiol       Date:  2002-02       Impact factor: 1.900

7.  Feasibility of cardiac cryoablation using a transvenous steerable electrode catheter.

Authors:  M Dubuc; M Talajic; D Roy; B Thibault; T K Leung; P L Friedman
Journal:  J Interv Card Electrophysiol       Date:  1998-09       Impact factor: 1.900

8.  Left ventricular catheter ablation using direct, intramural ethanol injection in swine.

Authors:  David J Callans; Jian-Fang Ren; Navneet Narula; Vickas Patel; John Michele; Anna Gelzer; Stephen M Dillon
Journal:  J Interv Card Electrophysiol       Date:  2002-07       Impact factor: 1.900

9.  'CLOSE'-Guided Pulmonary Vein Isolation and Changes in Local Bipolar and Unipolar Atrial Electrograms: Observations from the EP Lab.

Authors:  Mathieu Coeman; Milad El Haddad; Michael Wol; Rajin Choudhury; Yves Vandekerckhove; Rajin Choudhury; Sebastien Knecht; Rene Tavernier; Mattias Duytschaever
Journal:  J Atr Fibrillation       Date:  2018-02-28

10.  Factors influencing lesion formation during radiofrequency catheter ablation.

Authors:  Olaf J Eick
Journal:  Indian Pacing Electrophysiol J       Date:  2003-07-01
View more