Literature DB >> 7500217

Double-pass measurements of the retinal-image quality with unequal entrance and exit pupil sizes and the reversibility of the eye's optical system.

P Artal1, I Iglesias, N López-Gil, D G Green.   

Abstract

We have used a modified double-pass apparatus with unequal entrance and exit pupil sizes to measure the optical transfer function in the human eye and have applied the technique to three different problems. First, we confirm that in the eye the double-pass spread function is the cross correlation of the input spread function with the output spread function [J. Opt. Soc. Am. A 12, 195 (1995)]. Consequently, when entrance and exit pupil sizes are equal, phase information is lost from the double-pass images. Second, we show that in double-pass measurements the eye behaves like a reversible optical system. That is, when entrance and exit pupils are equal, the double-pass image results from two passes through an optical system having a transfer function that is the same in both directions. To test for reversibility in the living eye we have used a double-pass apparatus with different exit and entrance pupil sizes (one of them small enough to consider the eye diffraction limited), so that the ingoing and the outgoing transfer functions are different. The measured image quality was unchanged when the pupils were interchanged, i.e., when the first-pass entrance pupil size becomes the second-pass exit pupil size, and vice versa. Third, the technique provides a means for inferring the complete optical transfer function of the eye, including the phase transfer function, and the shape of the point-spread function.

Entities:  

Mesh:

Year:  1995        PMID: 7500217     DOI: 10.1364/josaa.12.002358

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  12 in total

1.  Shack-Hartmann wavefront-sensor-based adaptive optics system for multiphoton microscopy.

Authors:  Jae Won Cha; Jerome Ballesta; Peter T C So
Journal:  J Biomed Opt       Date:  2010 Jul-Aug       Impact factor: 3.170

2.  Representing the retinal line spread shape with mathematical functions.

Authors:  Yi-Rong Yang; Justin Wanek; Mahnaz Shahidi
Journal:  J Zhejiang Univ Sci B       Date:  2008-12       Impact factor: 3.066

3.  Simulation and analysis of light scattering by multilamellar bodies present in the human eye.

Authors:  Emilia M Méndez-Aguilar; Ismael Kelly-Pérez; L R Berriel-Valdos; José A Delgado-Atencio
Journal:  Biomed Opt Express       Date:  2017-05-19       Impact factor: 3.732

4.  Quantifying intraocular scatter with near diffraction-limited double-pass point spread function.

Authors:  Junlei Zhao; Fei Xiao; Jian Kang; Haoxin Zhao; Yun Dai; Yudong Zhang
Journal:  Biomed Opt Express       Date:  2016-10-17       Impact factor: 3.732

5.  Intensity analysis of Hartmann-Shack images in cataractous, keratoconic, and normal eyes to investigate light scattering.

Authors:  Toshifumi Mihashi; Yoko Hirohara; Kenichiro Bessho; Naoyuki Maeda; Tetsuro Oshika; Takashi Fujikado
Journal:  Jpn J Ophthalmol       Date:  2006 Jul-Aug       Impact factor: 2.447

6.  Evaluation of optical function using a new point spread function analysis system in cataractous and pseudophakic eyes: preliminary results.

Authors:  Kazuno Negishi; Katsuhiko Kobayashi; Kazuhiko Ohnuma; Kenji Ohno; Toru Noda
Journal:  Jpn J Ophthalmol       Date:  2006 Jan-Feb       Impact factor: 2.447

7.  Peripheral optical quality and myopia progression in children.

Authors:  Takefumi Yamaguchi; Kazuhiko Ohnuma; Kenji Konomi; Yoshiyuki Satake; Jun Shimazaki; Kazuno Negishi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-06-13       Impact factor: 3.117

8.  Comment on "Measurement and correction of transverse chromatic offsets for multi-wavelength retinal microscopy in the living eye".

Authors:  Pablo Artal
Journal:  Biomed Opt Express       Date:  2012-10-09       Impact factor: 3.732

9.  An objective scatter index based on double-pass retinal images of a point source to classify cataracts.

Authors:  Pablo Artal; Antonio Benito; Guillermo M Pérez; Encarna Alcón; Alvaro De Casas; Jaume Pujol; José M Marín
Journal:  PLoS One       Date:  2011-02-04       Impact factor: 3.240

10.  Evaluation of optical quality parameters and ocular aberrations in multifocal intraocular lens implanted eyes.

Authors:  Hun Lee; Kwanghyun Lee; Ji Min Ahn; Eung Kweon Kim; Bradford Sgrignoli; Tae-im Kim
Journal:  Yonsei Med J       Date:  2014-09       Impact factor: 2.759

View more