Literature DB >> 7498915

Magnetically induced currents in the canine heart: a finite element study.

P M Ragan1, W Wang, S R Eisenberg.   

Abstract

A moderately detailed three-dimensional (3-D) finite element model of the conductive anatomy of a canine thorax was used to determine the fields and currents induced by a time-varying magnetic field that has been shown to cause irregular heart beats in canines. The 3-D finite element model of the canine thorax was constructed from CT scans and includes seven isotropic tissue conductivities and the anisotropic conductivity of skeletal muscle. We use this model to estimate the stimulation threshold associated with stimulation of the heart by the time-varying magnetic field of a figure-eight coil. Variants of the thoracic model were also constructed to examine the sensitivity of model results to variations in model size, shape, and conductive inhomogeneity and anisotrophy. Our results show that myocardial fields were only midly sensitive to thoracic size. However, model shape and conductive inhomogeneity and anisotrophy substantially influenced the magnitude and distribution of myocardial fields and currents. Our results suggest that an induced peak field magnitude of approximately 1 V/cm is required to stimulate the heart with the magnetic excitation simulated in this study.

Entities:  

Mesh:

Year:  1995        PMID: 7498915     DOI: 10.1109/10.469378

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  5 in total

1.  Measurement of magnetostimulation thresholds in the porcine heart.

Authors:  Valerie Klein; Jaume Coll-Font; Livia Vendramini; Donald Straney; Mathias Davids; Natalie G Ferris; Lothar R Schad; David E Sosnovik; Christopher T Nguyen; Lawrence L Wald; Bastien Guérin
Journal:  Magn Reson Med       Date:  2022-07-30       Impact factor: 3.737

2.  Magnetic stimulation for non-homogeneous biological structures.

Authors:  Vessela T Krasteva; Sava P Papazov; Ivan K Daskalov
Journal:  Biomed Eng Online       Date:  2002-09-17       Impact factor: 2.819

3.  Peripheral nerve magnetic stimulation: influence of tissue non-homogeneity.

Authors:  Vessela T Z Krasteva; Sava P Papazov; Ivan K Daskalov
Journal:  Biomed Eng Online       Date:  2003-12-23       Impact factor: 2.819

4.  Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models.

Authors:  Valerie Klein; Mathias Davids; Lothar R Schad; Lawrence L Wald; Bastien Guérin
Journal:  Magn Reson Med       Date:  2020-08-19       Impact factor: 4.668

5.  Safety of MRI in patients with retained cardiac leads.

Authors:  Bach T Nguyen; Bhumi Bhusal; Amir Ali Rahsepar; Kate Fawcett; Stella Lin; Daniel S Marks; Rod Passman; Donny Nieto; Richard Niemzcura; Laleh Golestanirad
Journal:  Magn Reson Med       Date:  2021-12-27       Impact factor: 3.737

  5 in total