Literature DB >> 7494024

Detection of human immunodeficiency virus (HIV) type 1 antibodies by new automated microparticle enzyme immunoassay for HIV types 1 and 2.

L Matter1, D Germann.   

Abstract

We compared an automated microparticle double-antigen sandwich enzyme immunoassay (EIA) for the IMx test system recently developed by Abbott with two established assays (the automated indirect Vidas IgG EIA and the double-antigen sandwich EIA from Murex/Wellcome) devised for the detection of human immunodeficiency virus type 1 (HIV-1) and HIV-2 antibodies. A total of 1,078 consecutive serum samples were tested prospectively with the three assays. In addition, we used retrospectively selected panels of serum samples with discrepant results in two different screening tests and with indeterminate or positive Western immunoblot (WB) results, as well as five commercially available HIV-1 seroconversion panels. The new assay showed excellent discriminatory characteristics for the separation of samples from HIV-1-positive and HIV-1-negative persons according to Centers for Disease Control and Prevention WB criteria. The sensitivities were 98.1, 92.9, and 96.1% for the new test and the two other assays, respectively, and the specificities were 99.7, 97.9, and 98.1%, respectively. With the seroconversion panels this new test was positive several days earlier than the two other assays; i.e., seroconversion was evident at the peak of p24 antigenemia and often several weeks before WB became positive by the most stringent criteria.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7494024      PMCID: PMC228406          DOI: 10.1128/jcm.33.9.2338-2341.1995

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  10 in total

1.  Frequency of indeterminate western blot tests in healthy adults at low risk for human immunodeficiency virus infection. The NIAID AIDS Vaccine Clinical Trails Network.

Authors:  K Midthun; L Garrison; M L Clements; H Farzadegan; B Fernie; T Quinn
Journal:  J Infect Dis       Date:  1990-12       Impact factor: 5.226

2.  The fallibility of HIV western blot.

Authors:  P P Mortimer
Journal:  Lancet       Date:  1991-02-02       Impact factor: 79.321

3.  What do western blot indeterminate patterns for human immunodeficiency virus mean in EIA-negative blood donors?

Authors:  J Genesca; J W Shih; B W Jett; I K Hewlett; J S Epstein; H J Alter
Journal:  Lancet       Date:  1989-10-28       Impact factor: 79.321

4.  Evaluation of enzyme-linked immunosorbent assays: a method of data analysis.

Authors:  N Crofts; W Maskill; I D Gust
Journal:  J Virol Methods       Date:  1988-10       Impact factor: 2.014

5.  [Laboratory diagnosis in HIV infection].

Authors:  L Matter
Journal:  Schweiz Med Wochenschr       Date:  1991-08-24

6.  Ultrasensitive retrovirus detection by a reverse transcriptase assay based on product enhancement.

Authors:  H Pyra; J Böni; J Schüpbach
Journal:  Proc Natl Acad Sci U S A       Date:  1994-02-15       Impact factor: 11.205

7.  The Swiss HIV Cohort Study: rationale, organization and selected baseline characteristics.

Authors:  B Ledergerber; J von Overbeck; M Egger; R Lüthy
Journal:  Soz Praventivmed       Date:  1994

8.  Multicenter evaluation of a fully automated screening test, VIDAS HIV 1 + 2, for antibodies to human immunodeficiency virus types 1 and 2.

Authors:  J M Azevedo-Pereira; M H Lourenço; F Barin; R Cisterna; F Denis; P Moncharmont; R Grillo; M O Santos-Ferreira
Journal:  J Clin Microbiol       Date:  1994-10       Impact factor: 5.948

9.  Strategies for laboratory HIV testing: an examination of alternative approaches not requiring Western blot.

Authors:  P A Sato; W J Maskill; H Tamashiro; D L Heymann
Journal:  Bull World Health Organ       Date:  1994       Impact factor: 9.408

10.  Epstein-Barr virus infection in HIV-positive patients.

Authors:  A Telenti; D E Uehlinger; F Marchesi; D Germann; R Malinverni; L Matter
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1993-08       Impact factor: 3.267

  10 in total
  5 in total

1.  Multicenter evaluation of the new automated Enzymun-Test Anti-HIV 1 + 2 + subtyp O.

Authors:  B Weber
Journal:  J Clin Microbiol       Date:  1998-02       Impact factor: 5.948

2.  Evaluation and diagnostic usefulness of domestic and imported enzyme-linked immunosorbent assays for detection of human immunodeficiency virus type 1 antibody in India.

Authors:  H Syed Iqbal; Suniti Solomon; K G Murugavel; Sunil Suhas Solomon; P Balakrishnan
Journal:  Clin Diagn Lab Immunol       Date:  2005-12

3.  Performance characteristics of a new rapid immunochromatographic test for the detection of antibodies to human immunodeficiency virus (HIV) types 1 and 2.

Authors:  H Syed Iqbal; P Balakrishnan; K G Murugavel; Solomon Suniti
Journal:  J Clin Lab Anal       Date:  2008       Impact factor: 2.352

4.  Peptide-based antibody detection for tuberculosis diagnosis.

Authors:  Guomiao Shen; Digambar Behera; Manpreet Bhalla; Arthur Nadas; Suman Laal
Journal:  Clin Vaccine Immunol       Date:  2008-11-12

5.  Comparative assessment of commercial ELISA kits for detection of HIV in India.

Authors:  Srijita Nandi; Susmita Maity; Somesh Chandra Bhunia; Malay Kumar Saha
Journal:  BMC Res Notes       Date:  2014-07-07
  5 in total