Frequency of indeterminate western blot tests in healthy adults at low risk for human immunodeficiency virus infection. The NIAID AIDS Vaccine Clinical Trails Network.

K Midthun1, L Garrison, M L Clements, H Farzadegan, B Fernie, T Quinn.   

Abstract

As part of a phase 1 trial of a candidate AIDS vaccine, blood specimens were collected from 168 healthy adult volunteers at minimal or no risk for becoming infected with human immunodeficiency virus type 1 (HIV-1). These specimens were screened for evidence of HIV-1 infection by enzyme immunoassay (EIA) and the Biotech/Du Pont Western blot (n = 168), culture (n = 122), and polymerase chain reaction assay (n = 20). None of the subjects had a positive test result by any of these assays, but 32% had indeterminate Western blot tests, most of which demonstrated a single band of low intensity. The most common bands were p24 (47%), p55 (34%), and p66 (36%); envelope bands were unusual (gp41, 2%; gp120, 2%). No serum specimen collected after 2-11 months from individuals with indeterminate Western blot results was positive by EIA or Western blot. There was 91% agreement in the test results of the first and second serum samples when the same lot of Western blot kit was used but only 36% agreement when different lots were used. The Biotech/Du Pont Western blot kit thus frequently yields indeterminate test results in the absence of HIV-1 infection, the reproducibility of which is subject to lot-to-lot variability.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2230270     DOI: 10.1093/infdis/162.6.1379

Source DB:  PubMed          Journal:  J Infect Dis        ISSN: 0022-1899            Impact factor:   5.226


  19 in total

1.  Evaluation of an indirect immunofluorescence assay for confirmation of human immunodeficiency virus type 1 antibody in U.S. blood donor sera.

Authors:  M T Sullivan; H Mucke; S D Kadey; C T Fang; A E Williams
Journal:  J Clin Microbiol       Date:  1992-09       Impact factor: 5.948

Review 2.  Scientific surveillance and the control of AIDS: a call for open debate.

Authors:  G T Stewart
Journal:  Health Care Anal       Date:  1994-11

Review 3.  Frequency, causes, and new challenges of indeterminate results in Western blot confirmatory testing for antibodies to human immunodeficiency virus.

Authors:  Ming Guan
Journal:  Clin Vaccine Immunol       Date:  2007-04-04

4.  Rapid and specific detection of Sin Nombre virus antibodies in patients with hantavirus pulmonary syndrome by a strip immunoblot assay suitable for field diagnosis.

Authors:  B Hjelle; S Jenison; N Torrez-Martinez; B Herring; S Quan; A Polito; S Pichuantes; T Yamada; C Morris; F Elgh; H W Lee; H Artsob; R Dinello
Journal:  J Clin Microbiol       Date:  1997-03       Impact factor: 5.948

Review 5.  HIV diagnostic testing: evolving technology and testing strategies.

Authors:  Demetre Daskalakis
Journal:  Top Antivir Med       Date:  2011 Feb-Mar

6.  Serum antibodies to HIV-1 are produced post-measles virus infection: evidence for cross-reactivity with HLA.

Authors:  P V Baskar; G D Collins; B A Dorsey-Cooper; R S Pyle; J E Nagel; D Dwyer; G Dunston; C E Johnson; N Kendig; E Israel; D R Nalin; W H Adler
Journal:  Clin Exp Immunol       Date:  1998-02       Impact factor: 4.330

7.  Evaluation of Chiron HIV-1/HIV-2 recombinant immunoblot assay.

Authors:  R L Kline; D McNairn; M Holodniy; L Mole; D Margolis; W Blattner; T C Quinn
Journal:  J Clin Microbiol       Date:  1996-11       Impact factor: 5.948

Review 8.  Laboratory tests for detection of human immunodeficiency virus type 1 infection.

Authors:  N F Nuwayhid
Journal:  Clin Diagn Lab Immunol       Date:  1995-11

9.  Evaluation and diagnostic usefulness of domestic and imported enzyme-linked immunosorbent assays for detection of human immunodeficiency virus type 1 antibody in India.

Authors:  H Syed Iqbal; Suniti Solomon; K G Murugavel; Sunil Suhas Solomon; P Balakrishnan
Journal:  Clin Diagn Lab Immunol       Date:  2005-12

10.  False-positive human immunodeficiency virus enzyme immunoassay results in pregnant women.

Authors:  Laura G Wesolowski; Kevin P Delaney; Margaret A Lampe; Steven R Nesheim
Journal:  PLoS One       Date:  2011-01-27       Impact factor: 3.240