Literature DB >> 7491744

Experimental velocity profiles and volumetric flow via two-dimensional speckle tracking.

L N Bohs1, B H Friemel, G E Trahey.   

Abstract

The performance of a two-dimensional speckle tracking system in measuring in vitro laminar flow is evaluated. The system uses a pattern matching algorithm to track subresolution-sized speckle regions between successive ultrasonic 2D pulse-echo acquisitions in order to determine both the axial and the lateral components of velocity. In this study, multiple 2D vector velocity maps were acquired in real time using a calibrated laminar flow phantom, and then statistically analyzed off-line. At a 90 degrees transducer angle, volumetric flow rates computed from measured velocity profiles exhibited excellent linearity (R2 > 0.99), with a mean error of -6.1%, over the range 5-30 mL/s. At 105 degrees and 120 degrees, experimental volume flow rates also agreed well with actual rates, although measured velocity profiles appeared more irregular with decreasing Doppler angles. Velocity profiles estimated using sampled radio-frequency data rather than envelope-detected data were inconsistent due to an insufficient sampling rate and the quantization of the velocity grid. Results indicate that excellent flow velocity and volume rate estimates can be obtained from vector velocity measurements along a single line of sight, without a priori knowledge of the flow direction, at transducer angles near 90 degrees where Doppler instruments are prone to large errors.

Entities:  

Mesh:

Year:  1995        PMID: 7491744     DOI: 10.1016/0301-5629(95)00034-o

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  4 in total

1.  Physiological relevance of quantifying segmental contraction synchrony.

Authors:  Lauren Johnson; Bouchra Lamia; Hyung Kook Kim; Masaki Tanabe; John Gorcsan; David Schwartzman; Sanjeev G Shroff; Michael R Pinsky
Journal:  Pacing Clin Electrophysiol       Date:  2011-10-20       Impact factor: 1.976

Review 2.  Developments in cardiovascular ultrasound. Part 2: Arterial applications.

Authors:  P R Hoskins; P J Fish; W N McDicken; C Moran
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

Review 3.  Developments in cardiovascular ultrasound: Part 1: Signal processing and instrumentation.

Authors:  P J Fish; P R Hoskins; C Moran; W N McDicken
Journal:  Med Biol Eng Comput       Date:  1997-11       Impact factor: 2.602

4.  An H∞ strategy for strain estimation in ultrasound elastography using biomechanical modeling constraint.

Authors:  Zhenghui Hu; Heye Zhang; Jinwei Yuan; Minhua Lu; Siping Chen; Huafeng Liu
Journal:  PLoS One       Date:  2013-09-13       Impact factor: 3.240