Literature DB >> 7481902

Grafted bone used in acetabular reconstruction: assessment by SPECT scintigraphy.

Y Fujikawa1, T Torisu, M Takasita, S Masumi.   

Abstract

OBJECTIVE: To investigate incorporation of the grafted bone used for acetabular reconstruction.
DESIGN: Single photon emission computed tomography (SPECT) was carried out at the 1st, 6th, and 12th month after the operation and the uptakes on serial SPECT scintigrams were normalized. The horizontal histogram of scintigraphic activity at the level of the central grafted bone in the coronal image was designated the profile curve. PATIENTS: Seven patients who had undergone bipolar hip arthroplasty for osteoarthritis of the hip were randomly selected. RESULTS AND
CONCLUSION: Five of seven profile curves obtained at the 1st month demonstrated a single peak at the host-graft junction. The profile curve obtained at the 6th month showed two peaks at the host-graft junction and the periphery of the grafted bone in all patients. The profile curve at the 12th month showed slightly increased activity in the center of the grafted bone. This preliminary study demonstrates that comparison of the serial profile curves on SPECT is valuable in evaluating the progress of incorporation of the grafted bone in hip arthroplasty.

Entities:  

Mesh:

Year:  1995        PMID: 7481902     DOI: 10.1007/bf00941242

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  16 in total

1.  Long-term fate of the vascularized iliac crest bone graft for mandibular reconstruction.

Authors:  F N Lukash; N S Tenenbaum; G Moskowitz
Journal:  Am J Surg       Date:  1990-10       Impact factor: 2.565

2.  Failure of acetabular autogenous grafts in total hip arthroplasty. Increasing incidence: a follow-up note.

Authors:  R D Mulroy; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1990-12       Impact factor: 5.284

3.  Use of bipolar endoprosthesis and bone grafting for acetabular reconstruction.

Authors:  E G McFarland; D G Lewallen; M E Cabanela
Journal:  Clin Orthop Relat Res       Date:  1991-07       Impact factor: 4.176

Review 4.  The art of bone scintigraphy--technical aspects.

Authors:  M K O'Connor; M L Brown; J C Hung; R J Hayostek
Journal:  J Nucl Med       Date:  1991-12       Impact factor: 10.057

5.  Total hip replacement in congenital dislocation and dysplasia of the hip.

Authors:  J F Crowe; V J Mani; C S Ranawat
Journal:  J Bone Joint Surg Am       Date:  1979-01       Impact factor: 5.284

6.  The biology of bone graft repair.

Authors:  H Burchardt
Journal:  Clin Orthop Relat Res       Date:  1983-04       Impact factor: 4.176

7.  Bone scintigraphy in evaluating the viability of composite bone grafts revascularized by microvascular anastomoses, conventional autogenous bone grafts, and free non-revascularized periosteal grafts.

Authors:  A Berggren; A J Weiland; L T Ostrup
Journal:  J Bone Joint Surg Am       Date:  1982-07       Impact factor: 5.284

8.  Use of bipolar hip arthroplasty in states of acetabular deficiency.

Authors:  T Torisu; K Utsunomiya; M Maekawa; Y Ueda
Journal:  Clin Orthop Relat Res       Date:  1990-02       Impact factor: 4.176

9.  Autogenous cortical bone grafts in the reconstruction of segmental skeletal defects.

Authors:  W F Enneking; J L Eady; H Burchardt
Journal:  J Bone Joint Surg Am       Date:  1980-10       Impact factor: 5.284

10.  Femoral head autografting to augment acetabular deficiency in patients requiring total hip replacement. A minimum five-year and an average seven-year follow-up study.

Authors:  S D Gerber; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1986-10       Impact factor: 5.284

View more