Literature DB >> 7476088

A magnetization-driven gradient echo pulse sequence for the study of myocardial perfusion.

R M Judd1, S B Reeder, E Atalar, E R McVeigh, E A Zerhouni.   

Abstract

A T1-weighted imaging pulse sequence for contrast-based studies of myocardial perfusion is presented and evaluated in phantoms and in vivo. The sequence is similar to spoiled gradient-recalled echo sequences except that nonselective preparatory RF pulses drive magnetization to steady state prior to image acquisition. Steady state is thus obtained in both tissue and blood resulting in a stable, homogeneous, and dark pre-contrast baseline. Tip angles and timings are chosen so that pixel intensity approximates a linear relation to 1/T1. The dynamic range of signal response to contrast agent concentration is greater than that of an inversion-recovery fast low angle shot sequence. The sequence proposed should be useful for myocardial perfusion studies.

Mesh:

Substances:

Year:  1995        PMID: 7476088      PMCID: PMC2396271          DOI: 10.1002/mrm.1910340220

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  MRI susceptometry: image-based measurement of absolute susceptibility of MR contrast agents and human blood.

Authors:  R M Weisskoff; S Kiihne
Journal:  Magn Reson Med       Date:  1992-04       Impact factor: 4.668

2.  First-pass entry of nonionic contrast agent into the myocardial extravascular space. Effects on radiographic estimates of transit time and blood volume.

Authors:  J M Canty; R M Judd; A S Brody; F J Klocke
Journal:  Circulation       Date:  1991-11       Impact factor: 29.690

3.  In vivo relation of intramyocardial blood volume to myocardial perfusion. Evidence supporting microvascular site for autoregulation.

Authors:  X S Wu; D L Ewert; Y H Liu; E L Ritman
Journal:  Circulation       Date:  1992-02       Impact factor: 29.690

4.  Dependence of MR signal intensity on Gd tissue concentration over a broad dose range.

Authors:  M F Tweedle; P Wedeking; J Telser; C H Sotak; C A Chang; K Kumar; X Wan; S M Eaton
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

5.  Inversion recovery EPI of bolus transit in rat myocardium using intravascular and extravascular gadolinium-based MR contrast media: dose effects on peak signal enhancement.

Authors:  M F Wendland; M Saeed; K K Yu; T P Roberts; K Lauerma; N Derugin; J Varadarajan; A D Watson; C B Higgins
Journal:  Magn Reson Med       Date:  1994-09       Impact factor: 4.668

6.  Echo-planar MR imaging of normal and ischemic myocardium with gadodiamide injection.

Authors:  M F Wendland; M Saeed; T Masui; N Derugin; M E Moseley; C B Higgins
Journal:  Radiology       Date:  1993-02       Impact factor: 11.105

Review 7.  Susceptibility changes following bolus injections.

Authors:  M S Albert; W Huang; J H Lee; C S Patlak; C S Springer
Journal:  Magn Reson Med       Date:  1993-05       Impact factor: 4.668

8.  Studies of Gd-DTPA relaxivity and proton exchange rates in tissue.

Authors:  K M Donahue; D Burstein; W J Manning; M L Gray
Journal:  Magn Reson Med       Date:  1994-07       Impact factor: 4.668

9.  Regional heterogeneity of human myocardial infarcts demonstrated by contrast-enhanced MRI. Potential mechanisms.

Authors:  J A Lima; R M Judd; A Bazille; S P Schulman; E Atalar; E A Zerhouni
Journal:  Circulation       Date:  1995-09-01       Impact factor: 29.690

10.  Reperfusion and irreversible myocardial injury: identification with a nonionic MR imaging contrast medium.

Authors:  M Saeed; M F Wendland; Y Takehara; T Masui; C B Higgins
Journal:  Radiology       Date:  1992-03       Impact factor: 11.105

View more
  7 in total

1.  Quantitative hepatic perfusion modeling using DCE-MRI with sequential breathholds.

Authors:  Eric M Bultman; Ethan K Brodsky; Debra E Horng; Pablo Irarrazaval; William R Schelman; Walter F Block; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2013-11-04       Impact factor: 4.813

2.  Non-ECG-gated myocardial perfusion MRI using continuous magnetization-driven radial sampling.

Authors:  Behzad Sharif; Rohan Dharmakumar; Reza Arsanjani; Louise Thomson; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2014-01-17       Impact factor: 4.668

3.  All-systolic non-ECG-gated myocardial perfusion MRI: Feasibility of multi-slice continuous first-pass imaging.

Authors:  Behzad Sharif; Reza Arsanjani; Rohan Dharmakumar; C Noel Bairey Merz; Daniel S Berman; Debiao Li
Journal:  Magn Reson Med       Date:  2015-06-06       Impact factor: 4.668

Review 4.  Multiparametric MR Imaging in Abdominal Malignancies.

Authors:  Antonio Luna; Shivani Pahwa; Claudio Bonini; Lidia Alcalá-Mata; Katherine L Wright; Vikas Gulani
Journal:  Magn Reson Imaging Clin N Am       Date:  2016-02       Impact factor: 2.266

5.  Steady-state first-pass perfusion (SSFPP): a new approach to 3D first-pass myocardial perfusion imaging.

Authors:  Shivraman Giri; Hui Xue; Andrei Maiseyeu; Randall Kroeker; Sanjay Rajagopalan; Richard D White; Sven Zuehlsdorff; Subha V Raman; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2013-02-25       Impact factor: 4.668

Review 6.  Evaluation of the microcirculation: advances in cardiac magnetic resonance perfusion imaging.

Authors:  Amit R Patel; Frederick H Epstein; Christopher M Kramer
Journal:  J Nucl Cardiol       Date:  2008 Sep-Oct       Impact factor: 5.952

Review 7.  CMR of microvascular obstruction and hemorrhage in myocardial infarction.

Authors:  Katherine C Wu
Journal:  J Cardiovasc Magn Reson       Date:  2012-09-29       Impact factor: 5.364

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.