Literature DB >> 7472611

Automatic quantification of ejection fraction from gated myocardial perfusion SPECT.

G Germano1, H Kiat, P B Kavanagh, M Moriel, M Mazzanti, H T Su, K F Van Train, D S Berman.   

Abstract

UNLABELLED: We have developed a completely automatic algorithm to quantitatively measure left ventricular ejection fraction (LVEF) from gated 99mTc-sestamibi myocardial perfusion SPECT images.
METHODS: The algorithm operates in the three-dimensional space and uses gated short-axis image volumes. It segments the left ventricle (LV), estimates and displays endocardial and epicardial surfaces for all gating intervals in the cardiac cycle, calculates the relative left ventricular cavity volumes and derives the global EF from the end-diastolic and end-systolic volume, all without operator interaction. The algorithm for measuring LVEF was tested in 65 clinical patients undergoing 16-interval and 8-interval rest-gated SPECT and validated against first-pass radionuclide ventriculography.
RESULTS: Automatic segmentation and contouring of the LV was successful in 65/65 (100%) of the studies. Agreement between EFs measured from 8-interval gated SPECT and EFs calculated from first-pass data was high (y = 2.44 + 1.03x, r = 0.909, p < 0.001, s.e.e. = 6.87). Agreement between EF values measured from 16-interval and 8-interval gated SPECT was excellent (y = -2.7 + 0.97x, r = 0.988, p < 0.001, s.e.e. = 2.65), the latter being on average lower by 3.71 percentage points.
CONCLUSION: Our automatic method is rapid and highly agrees with conventional radionuclide measurements of EF, thus providing clinically useful additional information to complement myocardial perfusion studies.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7472611

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  369 in total

1.  Segmentation of gated Tl-SPECT images and computation of ejection fraction: a different approach.

Authors:  P Brigger; S L Bacharach; G Srinivasan; K A Nour; J A Carson; V Dilsizian; A Aldroubi; M Unser
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

2.  Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT.

Authors:  S D Van Kriekinge; D S Berman; G Germano
Journal:  J Nucl Cardiol       Date:  1999 Sep-Oct       Impact factor: 5.952

3.  Two- and three-dimensional assessments of myocardial perfusion and function by using technetium-99m sestamibi gated SPECT with a combination of count- and image-based techniques.

Authors:  T Nakata; Y Katagiri; Y Odawara; M Eguchi; M Kuroda; K Tsuchihashi; M Hareyama; K Shimamoto
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

4.  Comparison between segmental wall motion and wall thickening in patients with coronary artery disease using quantitative gated SPECT software.

Authors:  M B Imran; K Morita; I Adachi; M Konno; N Kubo; T Mochizuki; C Katoh; T Kohya; A Kitabatake; E Tsukamoto; N Tamaki
Journal:  Int J Card Imaging       Date:  2000-08

5.  Comparison of left ventricular function at rest and post-stress in patients with myocardial infarction: Evaluation with gated SPECT.

Authors:  C D Bavelaar-Croon; Y G America; D E Atsma; P Dibbets-Schneider; A H Zwinderman; M P Stokkel; E K Pauwels; E E van der Wall
Journal:  J Nucl Cardiol       Date:  2001 Jan-Feb       Impact factor: 5.952

6.  Proceedings of the 4th Invitational Wintergreen Conference. Wintergreen, Virginia, USA. July 12-14, 1998. Abstracts.

Authors: 
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

7.  Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging.

Authors:  P Vaduganathan; Z X He; G W Vick; J J Mahmarian; M S Verani
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

8.  Evaluation of left ventricular endocardial volumes and ejection fractions computed from gated perfusion SPECT with magnetic resonance imaging: comparison of two methods.

Authors:  T L Faber; J P Vansant; R I Pettigrew; J R Galt; M Blais; G Chatzimavroudis; C D Cooke; R D Folks; S M Waldrop; E Gurtler-Krawczynska; M D Wittry; E V Garcia
Journal:  J Nucl Cardiol       Date:  2001 Nov-Dec       Impact factor: 5.952

9.  The right stuff.

Authors:  Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

10.  Comparison between segmental wall motion and wall thickening in patients with coronary artery disease using quantitative gated SPECT software.

Authors:  S L Rahman; S R Underwood
Journal:  Int J Card Imaging       Date:  2000-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.