Segmentation of gated Tl-SPECT images and computation of ejection fraction: a different approach.

P Brigger1, S L Bacharach, G Srinivasan, K A Nour, J A Carson, V Dilsizian, A Aldroubi, M Unser.   

Abstract

BACKGROUND: We describe a set of image processing algorithms and mathematical models that can be advantageously used in schemes for the segmentation of thallium-201-single photon emission computed tomography (SPECT) images and for computation of left ventricular ejection fraction (EF).
METHODS: The system consists of two independent blocs for image segmentation and computation of function. The former is based on a multiresolution elliptical coordinate transformation and dynamic contour tracking. Computation of EF is formulated on the basis of both the endocardial and epicardial contours, and we compare this formulation with that using only the endocardial border for images with low signal-to-noise ratios. The accuracy of border detection was validated against manual border tracing on FDG-PET images, simulated Tl-201-SPECT images where the true underlying borders were known, and actual Tl-201-SPECT images. Finally, we compared EFs computed for FDG-PET, technetium-99m-SPECT and Tl-201-SPECT with those obtained from planar gated blood pool imaging.
RESULTS: The automatically obtained results always were within the manual uncertainty range. Agreement between myocardial volumes from positron emission tomography and automatically obtained values from the simulated Tl-201-SPECT images was excellent (r = 0.95, n = 32). Agreement between EFs from planar gated blood pool imaging and the other image modalities was good (FDG-PET: y = 5.89 + 1.21x, r = 0.92, see = 6.24, n = 19, Tc-99m-SPECT: y = -3.86 + 1.06x, r = 0.88, see = 7.78, n = 9, Tl-201-SPECT: y = 17.8 + 0.81x, r = 0.77, see = 7.44, n = 26). For noisy input data the combined use of information from epicardial and endocardial contours gives more accurate EF values than the traditional formula on the basis of the endocardial contour only.
CONCLUSIONS: Alternate approaches for segmentation and computation of function have been presented and validated. They might also be advantageously incorporated into other existing techniques.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10385184     DOI: 10.1016/s1071-3581(99)90041-7

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  20 in total

1.  Automated extraction of serial myocardial borders from M-mode echocardiograms.

Authors:  M Unser; G Pelle; P Brun; M Eden
Journal:  IEEE Trans Med Imaging       Date:  1989       Impact factor: 10.048

2.  Assessment of systolic thickening with thallium-201 ECG-gated single-photon emission computed tomography: a parameter for local left ventricular function.

Authors:  T Mochizuki; K Murase; Y Fujiwara; S Tanada; K Hamamoto; W N Tauxe
Journal:  J Nucl Med       Date:  1991-08       Impact factor: 10.057

3.  Measurement of myocardial wall thickening from PET/SPECT images: comparison of two methods.

Authors:  M L Bartlett; I Buvat; J J Vaquero; D Mok; V Dilsizian; S L Bacharach
Journal:  J Comput Assist Tomogr       Date:  1996 May-Jun       Impact factor: 1.826

4.  Measurement of left ventricular volume using single-photon emission computed tomography.

Authors:  G R Caputo; M M Graham; K D Brust; J W Kennedy; W B Nelp
Journal:  Am J Cardiol       Date:  1985-11-01       Impact factor: 2.778

5.  Parameter estimation of cardiac geometry by ECG-gated PET imaging: validation using magnetic resonance imaging and echocardiography.

Authors:  G Porenta; W Kuhle; S Sinha; J Krivokapich; J Czernin; S S Gambhir; M E Phelps; H R Schelbert
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

6.  A semi-automated method for edge detection in the evaluation of left ventricular function using ECG-gated single-photon emission tomography.

Authors:  K T Yang; H D Chen
Journal:  Eur J Nucl Med       Date:  1994-11

7.  A method for automatic edge detection and volume computation of the left ventricle from ultrafast computed tomographic images.

Authors:  E L Dove; K Philip; N L Gotteiner; M J Vonesh; J A Rumberger; J E Reed; W Stanford; D D McPherson; K B Chandran
Journal:  Invest Radiol       Date:  1994-11       Impact factor: 6.016

8.  Optimum fourier filtering of cardiac data: a minimum-error method: concise communication.

Authors:  S L Bacharach; M V Green; D Vitale; G White; M A Douglas; R O Bonow; S M Larson
Journal:  J Nucl Med       Date:  1983-12       Impact factor: 10.057

9.  Regional wall thickening of left ventricle evaluated by gated positron emission tomography in relation to myocardial perfusion and glucose metabolism.

Authors:  K Yamashita; N Tamaki; Y Yonekura; H Ohtani; Y Magata; R Nohara; H Kambara; C Kawai; T Ban; J Konishi
Journal:  J Nucl Med       Date:  1991-04       Impact factor: 10.057

10.  Determining the accuracy of calculating systolic wall thickening using a fast Fourier transform approximation: a simulation study based on canine and patient data.

Authors:  C D Cooke; E V Garcia; S J Cullom; T L Faber; R I Pettigrew
Journal:  J Nucl Med       Date:  1994-07       Impact factor: 10.057

View more
  2 in total

1.  Assessment of left ventricular ejection fraction with quantitative gated SPECT: accuracy and correlation with first-pass radionuclide angiography.

Authors:  E Vallejo; D P Dione; A J Sinusas; F J Wackers
Journal:  J Nucl Cardiol       Date:  2000 Sep-Oct       Impact factor: 5.952

2.  Deep learning based automatic segmentation of metastasis hotspots in thorax bone SPECT images.

Authors:  Qiang Lin; Mingyang Luo; Ruiting Gao; Tongtong Li; Zhengxing Man; Yongchun Cao; Haijun Wang
Journal:  PLoS One       Date:  2020-12-03       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.