An appreciation of the new St. Jude valvular prosthesis.

A Chaux, R J Gray, J M Matloff, H Feldman, H Sustaita.   

Abstract

Beginning in March, 1978, 88 patients have had cardiac valve replacements with St. Jude prostheses. There were 26 males and 62 females, aged 6 to 80 years (mean 60). Single valve replacement was done in 67. Double valve replacement was done in 21; 12 of them had two St. Jude valves and nine had a different second valve. There were 57 mitral and 43 aortic valves replaced. Thirty-six patients had concomitant aorta-coronary bypass, and six others had additional cardiac procedures. All patients have been followed for a total of 807 patient-months (mean 9 months). Seventy-nine have been receiving sodium warfarin and seven are not receiving anticoagulants. There has been one embolic episode. There are no valve failures to date. Early mortality is 2.3% and late mortality, 5.7%; no death was valve related. Fifty-three survivors have improved by two or more N.Y.H.A. classifications. Fifty-four valves studied postoperatively at rest, during pacing, and during isoproterenol infusion have demonstrated significantly better hemodynamic performance than have mitral porcine xenografts studied in an identical manner (p < 0.05). Phonocardiography, M-mode and two-dimensional echocardiography, and cinefluoroscopy, carried out in 18 patients, have proved to be reliable noninvasive techniques for long-term follow-up. This experience indicates that the St. Jude prosthesis offers an excellent and predictable alternative in the surgeon's decision-making concerning valve choices.

Entities:  

Mesh:

Year:  1981        PMID: 7453229

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

1.  New automated wavelet analytical system with a cellular phone for recording intercellular phone remote transmitted bileaflet valve sound.

Authors:  Takashi Sugiki; Hiroshi Sugiki; Norihiko Shiiya; Yoshiro Matsui; Kenji Sugiki
Journal:  J Artif Organs       Date:  2009-12-25       Impact factor: 1.731

2.  Wavelet analysis of valve closing sound detects malfunction of bileaflet mechanical valve.

Authors:  Hiroshi Sugiki; Toshifumi Murashita; Norihiko Shiiya; Yoshiro Matsui; Kenji Sugiki
Journal:  J Artif Organs       Date:  2008-04-15       Impact factor: 1.731

3.  Mid-term results of small-sized St. Jude Medical Regent prosthetic valves (21 mm or less) for small aortic annulus.

Authors:  Hiroki Mizoguchi; Masayuki Sakaki; Kazushige Inoue; Takashi Iwata; Keikou Tei; Takuya Miura
Journal:  Heart Vessels       Date:  2012-11-17       Impact factor: 2.037

4.  Aortic and mitral valve replacement with the St. Jude Medical prosthesis.

Authors:  F A Crawford; J M Kratz; R M Sade; M R Stroud; D M Bartles
Journal:  Ann Surg       Date:  1984-06       Impact factor: 12.969

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.